RESUME
V.MANIKANDAN
Testing & Commissioning – Team Leader
Email:-Mobile: UAE: -
Career Details:
Experience In
Total Years
GULF
INDIA
Project Engineer
2
1
1
Team Leader
6 months
6 months
0
13
9
4
Senior Testing &
Commissioning Engineer
Professional Details:
Technical Qualification:
Completed B.E (E.E.E) Arulmigu kalasalingam college of Engineering,
Anna University-2005, Tamilnadu, India.
Current Working Company
Arab Gulf Voltech Services Co. LLC.
PO Box: 54566|Flat # 3|Majed Al Muhairi Building |Abu Dhabi|U.A.E.
Client Approval (UAE): (Testing & Commissioning)
ADDC Protection Approval for CT, VT and Auxiliary Relays.
FEWA Approval for 33/11kV CT/VT, DC scheme, TCS, TSS, Auxiliary Relay,
LVAC and 33kV Bus bar Protection.
TRANSCO Approval for Scheme Checks including Interface, CT/VT Testing, Stability Checks.
Nature of Work Experience in Project Engineer:
Currently Working as a Project Engineer in AL Dabbiya Project (ADNOC- ARCHIRODON)
through Siemens LLC Abu Dhabi.
Review 33kV GIS SLD, GA & Schematic Diagram as per Specification Requirement.
Review 3.3kV GIS SLD, GA & Schematic Diagram as per Specification Requirement.
Review 415V SW & Distribution Boards Vendor Documents as per Specification Requirement.
Review Data Sheet, Fat Procedure & ITP Documents as per Customer Comments.
Review all Customer Comments as per Specification.
Electrical Equipment layout Review as per Customer Requirement.
Coordination with Vendor & Customer.
Prepare 3.3kv AIS Modification Drawing as per Customer Requirement.
Customer Commented Documents are resubmitted within Due dates.
Experience in ROXTEC Software. (MCT Preparation).
Prepared Material Request List For Individual Equipment.
Nature of Work Experience in Testing & Commissioning Engineer
Testing of various components like Circuit breakers, CT, VT, Aux relays.
LVAC, 11kV , 33kV & 132Kv & 400kV DC Scheme Checks
TCS & TSS scheme checks
CT Primary injection
CT/VT Secondary injection
Trip coil current measurement
CBF/ BB scheme checks
Trip logic.
Bus bar protection Sensitivity & Stability test.
Preparation of Pre commissioning check lists, test reports, as built drawings, cable schedules,
scheme modification and detailed commissioning schedules for the above mentioned systems.
Experience In TRANSCO NETWORK :( UAE)
Contract No
Name of the Project /
Contractor
Position / Responsibility
Team Leader / Prepare 2 weeks Look Ahead programme, Arrange
Testing Equipment’s on time, Collect Approved Schematic drawing
N15323
132/11kV Shakhbout
& Approved SAT procedure for all Equipment’s. Coordinate all the
Substation / NCC
Testing Activities. Attend Contractor & Consultant weekly Meeting,
prepare daily progress Report & Monthly Progress Report. Monitor
Everyday Testing Activities.
Senior Commissioning Engineer /400kV Cable Feeder END to END
271209
400kV Barakah Nuclear
Power Plant Stage-1 /
TOSHIBA
Test , 400kV Cable Stability Test, 400kV Intertrip Test, CT Primary
Injection, CT/VT Secondary Injection , DC Scheme Checks,
SCMS Signal checks Commissioning Activity.
Senior Commissioning Engineer / Testing & commissioning of
N7204.1C
132/11kV E25/02 Substation
/ ETA
132/11kV Transformer Stability test ,132kV Cable Stability Test,
132kV CT Primary Injection, 132kV Protection Panel Scheme
Checks, 132 kV Auxiliary Relays, 132kV CT/VT Secondary
Injection, 132kV SCMS Signals and LDC Integration.
Commissioning Engineer / Testing & commissioning of 22KV HV
132/22kV New Airport &
N6166.1
132/22KV Capital District
Substations. / SIEMENS
TEST Coordination, 22KV Interlock Checks, 22kV Scheme Checks,
22KV CT Primary Injection, 22KV VT & CT Secondary Injection, ,
22kV SCMS Coordination, and Preparation of as built schematic
diagram, cable schedule and Termination Schedule.
132/11kV W2 &
N4351.1B
Commissioning Engineer / Testing of 11KV HV TEST
132/11kV Khalifa II A
Coordination, 11KV Interlock Checks, 11KV CT Primary Injection,
Substation / SIEMENS
11KV Auxiliary Relay, 11KV CT & VT Test, 11KV VT /CT
Secondary Injection and 11KV SCMS Signals.
Commissioning Engineer / Testing & Commissioning of 132KV
N4351.1A
132/11kV W24 Substation /
HYUNDAI
Interlock Checks, 132KV Annunciation Checks, 11KV Interlock
checks, 11KV CT /VT TEST, 11KV Scheme Checks, LVAC ADDC
/ TRANSCO Scheme Checks, and 48V DC Battery Charger
commissioning coordination.
Commissioning Engineer / Testing & commissioning of 22KV
N5071.2
132/22kV SS4,SS5
Substation / HYUNDAI
Interlocks checks, 22KV HIGH VOLTAGE TEST coordination,
22KV Scheme Checks, 22kV CT/VT Test, 22KV SCMS
Coordination., cable schedule & Termination Schedule.
Experience In FEWA NETWORK :(UAE)
Contract
Name of the Project /
No
Contractor
132/33/11kV FEWA
71E/2015
TAMN Substation/
MITSUBISHI
E3/09(1)
132/33/11kV Nakheel PS
Substation / SIEMENS
Position / Responsibility
Senior Commissioning Engineer/ 33kV Switchgear & LVAC, CT/CT
Test, Ammeter/Voltmeter Calibration, DC Scheme Checks, Interlock
Checks, Primary Injection Test, Alarm/Indication Checks, ELR TRIP
TEST.
Commissioning Engineer / Testing & Commissioning of
11kV Busbar protection scheme checks, LVAC All Equipment Test &
Preparation of as built schematic diagram.
Experience In KHARAMAA NETWORK :( QATAR)
Contract
Name of the Project /
No
Contractor
400/220/132/66/11 KV
-
Commissioning Engineer / Testing & Commissioning of CT Primary
AL Wajbah Super
Injection, CT Test , CT/VT Secondary injection, Trip Logic , TCS ,
Substation / ABB
and preparation of as built schematic diagram.
220/132/33/11 KV
-
Position / Responsibility
Ras Laffan Super
Main-3 Substation /
SIEMENS
Commissioning Engineer / Testing & Commissioning of CT Primary
injection, CT /VT Test, CT/ VT Secondary injection, Overcurrent &
Earth fault Relay Test ,Trip Logic, TCS & 132kV Protection Panel
Scheme Checks .
Experience in INDIA:
Name of the Project / Contractor
SUBBURAJ PAPER MILLS LTD, T.N
/ SIEMENS
Position / Responsibility
Commissioning Engineer / Testing & Commissioning of 11KV
Switchgear , CT /VT, LT Motors , PCC & MCC Scheme Check ,
11KV/415 Transformer, Protection relays & cable HI Voltage Test.
Commissioning Engineer / Testing & commissioning of 230kV
230/33 KV Substation, T.N / G.E.T
Switchyard, Circuit Breaker, CT /VT, 230kV/33kV Transformer,
Cable High Voltage Test, Protection relays & Scheme Checks.
Commissioning Engineer / Testing & Commissioning of 110kV
110/11kV Substation K.N / G.E.T
Switchyard, SF6 Breaker, CT/VT , 11kV/415V Transformer , Battery
Charger , Scheme Checks.
Commissioning Engineer / Testing & Commissioning 11kV
ITC PAPER PLANT,
BHATRACHALAM, A.P /SIEMENS
Switchgear, 6.6kV Switchgear, 3.3 kV Switchgear, HT Motors, PCC
& MCC Scheme Check, 11KV/415 Transformer Test &
Protection relays Test.
Personal Details:
Permanent Address
Date Of Birth
:-
Nationality
: INDIAN
Sex
: MALE
Marital Status
: MARRIED
Passport Number
: M-
Visa Type
: Employment Visa, UAE
Visa Expiry
: April 2021
: 1/87 Mullikulam,
Malli(post),
Srivilliputtur taluk ,
Virudhunagar (D.T)-626141
TAMILNADU,
INDIA.
Declaration
I hereby declare that all information given above is correct and true to the best of
my knowledge.
(MANIKANDAN.V)