KRISHNENDU SAMADDER
Email ---/-)
NATIONALITY :
INDIAN.
LOCATION :
KOLKATA.
DATE OF BIRTH :
15th Nov 1977
EDUCATION QUALIFICATION :
Diploma in Mechanical Engineering.
OTHER QUALIFICATION :
NDT Level II in RT, MPT, LPT, UT & VT.
SUMMARY OF WORK :
Inspection of Pressure Vessels, Atmospheric Storage Tanks in Different Sizes, Mounded Bullets, Pumps, Heat Exchangers, Condensers, General fabrication fames, skids, structures, In-process inspection of pipes (API 5L), Mechanical (rotating equipment) Pumps, Valves, Pipes, Pipe fittings, (Elbow. Reducer, Tee, Flanges, Socket, Bend etc.) Field Expediting & Different Types Brought-out Items, casting materials, forged items, Springs, air receiver, Draft Tube Cone, Impeller, Blower, Compressor, Gear Box, valves, Electrical hardware items Inspection and Testing under statutory Rules.
EXPERIENCE:
5. BUREAU VERITAS - Kolkata.
Duration: Sept-2020 to till date.
Position: Mechanical Inspection Engineer. (Freelancer)
Duration : From Nov’2020 to till date.
Client : WELSPUN CORP LTD, TATA, BPCL, IOCL, TECHNO Electric, ADANI GAS. INDUS,
TUAMAN Engg Ltd.
Attend SAIL, Bokaro for Hot Rolled Coil Inspection.
Inspection of Hot rolled steel coils (6.4 X 1387mm – 5373 MT) carried out as per manufacturing procedure
Specification & Inspection test plan at SAIL – Bokaro.
Mechanical lab test witnessed (Tensile test, Bend test, Impact test, Hardness test, Chemical analysis).
Dimensions verified (Thickness, Width).
Marking verified (Heat No, Coil no, Size).
Verified Mill Test Certificates as per manufacturing procedure Specification & Inspection test plan.
Attend at Jindal (I) Ltd, for API 5Lpipe inspection.
Pipe inspection carried out (Online) Coating (3LPE) as per QAP & Spec for ADANI GAS.
Casting items, Forged Items & Machining items were inspected at various locations as per PO, QAP & Spec for TATA Steel Ltd.
Pipe fittings & Flanges were inspected at various locations as per PO, QAP & Spec for TATA Steel Ltd.
Tower structural materials were inspected at various locations as per PO, QAP & Spec for INDUS & Tuaman Engg Ltd.
4.
Intertek Moody International (I) Pvt. Ltd.
Duration: July-2011 Sept-2020.
Position: Inspection Engineer.
Project : Megalift Irrigation project, Odisha, Cluster – IV & Malkangiri. Supplier - TATA
Metaliks (Kharagpur), Electrosteel (Khardah), Sail (Rourkella), Castleton
(Howrah), G M Dolui(Howrah), Vijay Transmission(Raipur) etc.
Indus Tower. Supplier – K L Mechanical & Solux Galfab Pvt Ltd.
Duration : From August’2018 to Sept’ 2020.
Inspection of DI Pipes & Fittings Witnessing Hydro-test at different Pressure at Electro steel & TATA Metaliks, Checked Mechanical & Physical properties. Checked dimension, Thickness (Cement mortar lining, bituminous paint & metal thickness).
Pipes inspection at Sail, Rourkella as per QAP.
Valve inspection carried out at G M Doului & sons, howrah as per QAP.
Structural items inspect at Vijay transmission Raipur.
Tower structural materials inspect at K L Mechanical- Dankuni & Solux galfab Pvt Ltd- howrah.
Project : ENORE-THIRUVALLUR-BENGALURU-PUDUCHERRY-NAGAPATTINAM- MADURAI-
TUTICORIN GAS PIPELINE PROJECT.
Owner : IOCL
Client/PMC : IOCL
Supplier : Jindal (I) Pvt. Ltd. (457 mm OD X 7.92 mm, 457 mm OD X 9.53 mm, 457 mm OD X
11.91 mm – as per API 5L)
Duration : From July’2020 to August’2020.
Online Pipe (API 5L) inspection including PQT (Production Qualification Test) in behalf of IOCL.
Plant monitoring, welding parameter check during Pipe rolling or manufacturing.
Hydro test & Cyclic Hydro test witnessed as per approved procedure, inspection test plan & Specification.
AUT (Automatic ultrasonic testing) Test Body & Weld witnessed as per approved procedure, inspection test plan & Specification.
MUT (Manual ultrasonic testing) of the pipe edge area weld & body or Indication area which were indicated by AUT -witnessed & verified as per approved procedure, inspection test plan & Specification.
MPI test witnessed of Bevel area of pipes as per approved procedure, inspection test plan & Specification.
Mechanical test witnessed (Tensile, Impact, Hardness, DWTT, Flattening & RBT, Chemical analysis) as per approved procedure, inspection test plan & Specification.
Visual inspection & Dimensions verified during final inspection (Length, Thickness, straightness, OD verified- etc.) as per approved procedure, inspection test plan & Specification.
3 LPE coating inspection of regular production (Lab test, Peel test, Impact test- etc.) as per approved procedure, inspection test plan & Specification.
Final Inspection of 3LPE coated pipes verified as per approved procedure, inspection test plan & Specification.
Project : Construction of 3 ETP’s along with laying of associated GRE Pipe lines @ Mehsana
Asset.
Owner : ONGC
Client/PMC : ONGC
Supplier : MEIL
Duration : From Oct’2018 to Sept’2019.
Full responsibility of manufacturing Raw-Effluent Tank, Treated water Tank as per API 650.
Monitoring & witnessing of Plate cutting, Marking, Fit UP, Welding inspection, RT spot selection, RT Film review, DP test, Oil Chalk test, Vacuum test of tank bottom, Pneumatic test & Hydro test as per approved procedure & specification.
Piping Lay-out, Welding parameter checking, Hydro Testing witnessed as per approved procedure & specification.
Project : NTPC - TANDA II, Telangana project, Ghatampur Project, Hassyan Project.
Owner : NTPC
Client/PMC : GE (Alstom)
Supplier : TEMA India Ltd (Vapi), Sulzer Pump (Navi Mumbai), KSB Pump (Pune), Bharat
Forge(Pune), L & T (Hazira)
Duration : From August’2017 to July’ 2018.
Inspection of Heat Exchangers, Condensers as per approved ITP, Drawing, Specification & Standard (ASME Sec VIII Div. – 1, ASME Sec IX, ASME Sec V) at TEMA India Ltd (Vapi).
Witnessed all test as per Procedure (DPT Test, UT Test, Radiography film reviewed, Hydro test Shell side, Hydro test Tube side, Helium leak test, Mechanical & Chemical lab test, Phenumatic test, Painting DFT verified, PWHT Chart Reviewed & Dimensions verified).
Project : EPC FOR AL DABB’IYA FACILITIES DEVELOPMENT PHASE III
Owner : Abu Dhabi Company for Onshore Petroleum Operations Ltd. (ADCO)
Supplier :TECNIMONT
Sub Supplier : Virgo Valves & Controls Pvt. Ltd. PUNE
Duration : From April’2017 to July’2017.
Inspection of ball valve as per ITP, approved drawing, specification & Standard. (API 6D, ASME B16.34)
Checked PMI, DPT test, MPI test, Hydro Shell test, Hydro Seat test, Hydro Pneumatic test, FET test (Helium leak test), Dimension checked, Blasting & painting checked as per Inspection Test plan, Approved Procedure & approved Drawing.
Project : SATAH AL-RAZBOOT (SARB) FIELD DEVELOPMENT
Owner : ADMA
Client/PMC : HYUNDAI ENGG & CONSTRUCTION CO.LTD.
Supplier : Virgo Valves & Controls Pvt. Ltd. PUNE
Duration : From Feb’2016 to Nov’2016.
Inspection of ball valve as per ITP, approved drawing, specification & Standard. (API 6D, ASME B16.34)
Checked PMI, DPT test, MPI test, Hydro Shell test, Hydro Seat test, Hydro Pneumatic test, FET test (Helium leak test), Dimension checked, Blasting & painting checked as per Inspection Test plan, Approved Procedure & approved Drawing.
Project : IOCL - PHDPL
Owner : IOCL
Client/PMC : IOCL
Supplier : Jindal (I) Pvt. Ltd. (12”x 6.34 mm -API 5L, 12”x 11.35 mm - API 5L, 16”x 11.35 mm -
API 5L, 16”x 9.5 mm - API 5L, 16”x 6.34 mm - API 5L)
Duration : From Nov’2015 to Jan’2016.
Online Pipe (API 5L) inspection including PQT (Production Qualification Test) in behalf of IOCL.
Plant monitoring, welding parameter check during Pipe rolling or manufacturing.
Hydro test & Cyclic Hydro test witnessed as per approved procedure, inspection test plan & Specification.
AUT (Automatic ultrasonic testing) Test Body & Weld witnessed as per approved procedure, inspection test plan & Specification.
MUT (Manual ultrasonic testing) of the pipe edge area weld & body or Indication area which were indicated by AUT -witnessed & verified as per approved procedure, inspection test plan & Specification.
MPI test witnessed of Bevel area of pipes as per approved procedure, inspection test plan & Specification.
Mechanical test witnessed (Tensile, Impact, Hardness, DWTT, Flattening & RBT, Chemical analysis) as per approved procedure, inspection test plan & Specification.
Visual inspection & Dimensions verified during final inspection (Length, Thickness, straightness, OD verified- etc.) as per approved procedure, inspection test plan & Specification.
3 LPE coating inspection of regular production (Lab test, Peel test, Impact test- etc.) as per approved procedure, inspection test plan & Specification.
Final Inspection of 3LPE coated pipes verified as per approved procedure, inspection test plan & Specification.
Project : 2 X 1000 MT CAPACITY LPG STORAGE MOUNDED PRESSURE VESSELS
(ASME SEC VIII DIV- II). IOCL- PHDPL Pipe line Division. Haldia.
Owner : IOCL.
Client/PMC : Mott Macdonald Pvt. Ltd.
Supplier : IOTL.
Duration : From July’2014 to Oct’2015.
Inspection of Incoming Raw Materials (Visual, Review of Test Certificates for adequacy), under Owner.
Fabrication & Erection of shell, Stiffener Ring plates, Dish.
Planning and supervision of welding activities, interpretation of radiographs and attending to NDT Activities.
Generate Day-to-day activities through proper documentation of Quality department and co-ordinate with inspection activities.
Known about post weld heat treatment (Internal Oil firing method & Electric Induction method).
Familiar with Mounded Bullet Drawing.
Familiar with ASME SEC VIII Div1, Div2, ASME SEC V & ASME SEC IX.
Vendor Inspection activity for Different items.
Inspection of Valves, Ball valves, Pipes, Pipe Fittings, Actuator, Air-Filter, Coupling, Gear Box, Casting Materials, Forged & Rolled Bar, Spring, Machining Items, turbines, Hydrolic Jack, Pressure Hoses, Stay Wire, Mineral wools, Wrapping & Coating materials (Coal tape, Bituminous paint) & Different Types Brought-out Items. (Industrial)
Client: BHEL, IOCL, Alstom, MPPKVCL, Paharpur Cooling Tower. TOYO, SAIL, Electro steel,
Jai Balaji, MMPL etc.
INSPECTION ACTIVITY
Inspection was carried-out as per Client requirement (PO, Spec, Drawing, QAP, Technical data Sheet etc.)
Inspection of Every Items Dimensions verified with drawings.
Inspection of Different Items as required NDT test (Ultrasonic Test, Liquid Penetrant test, Magnetic Particle test & radiographic test) Witnessed.
Witnessed of Mechanical & Physical properties of materials at Different Lab.
Painting Checked through Elco-meter.
FORGED & ROLLED BAR
Inspection of forged and rolled bars of different BHEL standard and witnessing of mechanical test and NDT (UT) involved at SAIL, Super Forging, Vikrant Forge, ARCVAC Forgecast at Kolkata & Durgapur.
CAST ITEMS
Inspection of Aluminium casting items like Blower, Insert Cover, Oil Catcher, Bull Ring (At AIA Engg- Ahmadabad) etc. and witnessing NDT (DP) and mechanical test.
Inspection of steel cast items like various Ring sections, Bush housing, Guide Vane etc with NDT (UT, DP,MPI) witness at Hindustan Udyog Ltd.
PIPES & PIPE FITTINGS.
Inspection of Pipes Witnessing Hydro test at different Pressure at JINDAL PIPES, TATA, MS Fittings at Kolkata.
Checked Dimension, Mechanical & Physical test.
GEAR BOX
Inspection of Gear-Box (Air Preheater & Tube Mill) Witnessing NO-Load Run Test for 4Hrs at SIMENS, NEW ALLENBERRY at Kolkata & Kharagpur.
Checked Required RPM, Dimension, Noise Level, Vibration and Temperature.
COMPRESSOR
Inspection of Compressor Witnessing Run Test & Performance test for 4Hrs at Ingersoll rand in Ahmadabad.
Checked Required RPM, Vibration, Noise level, Temperature rise.
Major Dimensions Checking.
BLOWER
Inspection of Blower Witnessing Run Test & Performance test for 1Hrs at Vaccunair in Ahmedabad.
Checked Required RPM, Vibration, Noise level, Temperature rise.
Major Dimensions Checking.
VALVE
Inspection of various Engineering Product such as Valves, Pumps Flanges etc, witnessing various tests as per ASTM / ASME Code and Client specifications
Product Inspection of Steel compact carbon steel valves of various sizes and types as per API – 600, API – 602.
Expediting and Inspection of Ball Valves, Gate Valves.
Checked Actuator operated valve.
Inspection of Valves (Butterfly Valves, Globe Valves, Ball Valves) Witnessing Hydro test at different Pressure at VENUS PUMP, DUMDUM VALVES.
Inspection of Valves of different sizes and class.
DI PIPES & DI Pipe Fittings.
Inspection of Pipes Witnessing Hydro-test at different Pressure at Electro steel & Jai Balaji.
Checked Mechanical & Physical properties.
Checked dimension, Thickness (Cement mortar lining, bituminous paint & Ductile Iron).
HYDROLIC HOSES
Inspection of Hydrolic Pressure Hoses Witnessing Hydro test at different Pressure at SONY RUBBER & Precession Industrial Hoses at Kolkata.
SPRING
Inspection of Spring Witnessing Load Test, Cramp Test, Scragging Test at BP SPRING, All India spring, Bhartia mini spring & Caselton at Kolkata.
Mechanical lab test Witnessed.
ROTATING DEVICE (COUPLING, IMPEELLER, INDUSTRIAL FAN)
Inspection of Coupling, Impeller, Industrial Fan- Witnessing Dynamic Balancing Test at ANDRULE, WELLMAN WOCOMO.
CORROGATED ALLUMINIUM SHEET.
Inspection of Corr. Aluminum Sheet lab test, Dimensional checked at HINDALCO, NALCO at Kolkata & Bhubaneswar.
CABLE TRAY & ACCESSORIES.
Inspection of Cable tray and accessories and witnessing Deflection Test and Galvanizing Test at Premier Power Product
STAY WIRE
Inspection of Stay Wire, GI Pin etc and Mechanical test (Tensile test, Wrap test) and Galvanizing test witnessed on behalf of MPPKVVCL.
FABRICATED ITEMS
Inspection of different types fabricated items like Air-port ring, Air receiver, Chute, Pressure Vessels etc. at different Manufacturers Place with different NDT Activities.
3.
Vijay Tanks & Vessels Limited. (BARODA)
Duration : FEB 2005 to JUNE 2011
Position : Inspection Engineer.
PRESSURE VESSELS (BULLETS & STORAGE TANK) (As per API 650 & PD 5500).
(IV) At JINDAL STEEL & POWER Ltd.- Qrissa/Angul Site. Project- Coal Gasification Project. (28 Nos Tanks (Different Sizes, 3Bullets (2Nos- 56 mtr Length X 7 mtr ID1, 1Nos – 16mtr Length X 4mtr ID) Client – Jindal. Inspection- BV / JINDAL. (From 20/05/2011 June 2011)
Inspection of Incoming Raw Materials (Visual, Review of Test Certificates for adequacy), under 3rd party’s inspection (BV).
Joint fit-up, Orientation inspection as per approved drawings.
Fabrication & Erection of tank bottom, shell, Roof plates, Roof Structures.
Planning and supervision of welding activities, interpretation of radiographs and attending to rectification and repair work.
Day-to-day functioning of Quality department and co-ordination of inspection activities & interpretation of radiographs.
Maintain the proper documentation.
Familiar with API 650 & PD5500 (British Standard).
ATMOSPHERIC STORAGE TANK & PIPE LINE (As per API 650, ASME B 31.3).
(III) At Gujarat Chemical Port Terminal Company Ltd.- Dahej Site. Project- Acetic Acid
Handling Facilities. 1 Nos SS Tank (26 mtr ID X 17 mtr Ht) & Piping, Client – REAL. (From
03/04/2010 to 17/05/2011)
Procedures for Hydro testing (Tank & Piping), Painting Procedures, Welder’s test and welder Performance qualification, NDT Procedures (PT, MPT, RT, UT, OCT, Vacuum Box test, Pickling & Passivation, Wrapping & Coating (for Piping).
Inspection of Incoming Raw Materials (Visual, Review of Test Certificates for adequacy), under client’s inspection (REAL).
Fabrication & Erection of tank bottom, shell, Roof plates, Roof Structures.
Planning and supervision of welding activities, interpretation of radiographs and attending to rectification and repair work.
Day-to-day functioning of Quality department and co-ordination of inspection activities & interpretation of radiographs.
Detailing specific procedures (methodology- sequence of operations) for fabrication & Erection activities to satisfy quality requirements.
To qualify the welders through test.
Preparation of weld markup drawings as per approved drawings.
Joint fit-up inspection as per approved drawings.
Surveillance inspection of welding consumable control.
Final weld visual inspection & NDT review in accordance to Code & Specifications.
Maintain the proper documentation.
Welding procedure qualification, Site surveillance & Punch listing, Compilation of Completed Package.
Familiar with API 650.
PRESSURE VESSELS (ATMOSPHERIC STORAGE TANK & MONDED BULLET) (As per API 650 & ASME SEC VIII DIV- I).
(II) At IOCL-Baroda. Project- Sulpher Recovery Unit. (9 Nos Fabricated Storage Tank 12mtr ID X 12mtr Ht -4 Nos, 12’6 mtr ID X 12 mtr Ht -2 Nos, 15mtr ID X 15 mtr Ht -2 Nos & 10mtr ID X 10mtr Ht -1 Nos) 7mtr ID X 90 mtr Long - 3 Nos Mounded Bullet. Client – L&T. (From 12/11/2008 to 02/04/2010)
Inspection of Incoming Raw Materials (Visual, Review of Test Certificates for adequacy), under PMC (TOYO), Client (L&T) & Third party (TUV) inspection.
Fabrication & Erection of tank bottom, shell, Roof plates, Roof Structures.
Planning and supervision of welding activities, interpretation of radiographs and attending to NDT Activities and repair work.
Generate Day-to-day activities through proper documentation of Quality department and co-ordinate with inspection activities.
Known about post-weld heat treatment (Internal Oil firing method & Electric Induction method).
Familiar with Tankage Drawing.
Familiar with API 650.
ATMOSPHERIC STORAGE TANK (As per API 650).
(I) At Jamnagar (Atmospheric Storage Tank, Internal Flooting Roof Tank 92mtr ID X 20mtr Ht, 56 mtr ID X 20mtr Ht, 46 mtr ID X 20 mtr Ht.) Client- REAL. (From 04/02/2005 to 10/11/2008).
Fabrication & Erection of tank bottom, shell, Deak plates, Deak Structures.
Planning and supervision of welding activities, interpretation of radiographs and attending to NDT Activities under client’s inspection (REAL).
Day-to-day functioning of Quality department and co-ordination of inspection activities VBT, Oil chalk test, DPT. MPT, SR chart review & RT film review.
Detailing specific procedures (methodology- sequence of operations) for fabrication & Erection activities to satisfy quality requirements.
Knowledge about deak openings-like pipe support & sleeve, Rim vent, Bleeder vent, Emergency drain, Roof drain, Rolling ladder, Gauge-well and etc.
Familiar with API 650.
2.
RAIL-UDYOG Kolkata.
Duration : March 2003 to JAN 2005
Position : Shop Supervisor.
Inspection of Incoming Raw Materials (Visual, Review of Test Certificates for adequacy).
QA/QC Documentation.
Preparation of heat treatment records.
Preparation and monitoring of schedules for heat treatment.
1.
FENNER INDIA LIMITED. Kolkata.
Duration : JANUARY 2002 to FEB 2003
Position : Worked as Sales & Service Engineer.
For sailing of V-Belt, Pulley, Coupling, Gear-box (Power transmission element) in the respective Industries.
Personal information:
Present address. : Krishnendu Samadder.
130/3, Aguripara, PO – Kanchrapara, Dist -24PGS (N)
Pin- 743145.
Father’s Name : Kalinga bhusan samadder.
Maretial status : Married.
Language Known : Bengali, Hindi, English.
Last Salary : 54133 per month +TA.
Current job Location : Kolkata.
Preferred Job Location : Kolkata.
Krishnendu Samadder.
Place: Kolkata.
Date: 13/08/2021