REVISIONS
NO.
DATE
DESCRIPTION
MULTIFAMILY RESIDENCE DEVELOPMENT
EXISTING BUILDING BLOCK 10304, LOT 3
ARCHITECT:
ADDRESS: 346 CENTRE ST, TRENTON, MERCER COUNTY N.J 08611
ABBREVIATIONS:
AUGUSTUS GEHRY
ARCHITECT
A.
AT
ABOVE FINISHED FLOOR
ALUMINUM
APPROXIMATELY
BD
BFE
BLDG
BM
BOT
BOF
BEAR
BSMT
BOARD
BASE FLOOR ELEVATION
BUILDING
BEAM
BOTTOM
BOTTOM OF FOOTING
BEARING
BASEMENT
CJ
CLG
CLR
CMU
CO
COMP
CONC
CONT
CPT
CT
CEILING JOISTS
CEILING
CLEAR
CONCRETE MASONRY UNIT
CLEAN OUT
COMPOSITE
CONCRETE
CONTINUOUS
CARPET
CERAMIC TILE
DIA
DIM
DIST
DN
DS
DIAMETER
DIMENSION
DISTANCE
DOWN
DOWN SPOT
E
EA
ELEV
EQ
EQUIP
EXP
EXIST
EXT
EAST
EACH
ELEVATION
EQUAL
EQUIPMENT
EXPOSED
EXISTING
EXTERIOR
FD
FFE
FJ
FLD
FLR
FT
FTG
FLOOR DRAIN
FINISHED FLOOR ELEVATION
FLOOR JOISTS
FIELD
FLOOR
FOOT / FEET
FOOTING
C.
A.
THESE DRAWINGS ARE AN INSTRUMENT OF SERVICE AND REMAIN THE PROPERTY OF THE ARCHITECT AND OR OWNER OF THE PROPERTY CONCERNED TO USE AS HE SEES FIT. THESE DRAWINGS SHALL NOT BE USED
WITHOUT THE ARCHITECT'S OR OWNER'S OF THE PROPERTY CONSENTS. DRAWINGS SHALL NOT BE USED FOR ISSUE OF THE BUILDING PERMIT UNLESS SIGNED AND SEALED BY THE ARCHITECT OR OWNER OF THE PROPERTY.
STRUCTURE/BUILDING DELINEATED HEREIN.
B.
THESE DRAWINGS REPRESENT AN OVERALL DESIGN CONCEPT. THEY PREPARED WITH THE INTENT TO DEMONSTRATE THE OVERALL DESIGN ARRANGEMENT AND METHOD OF ASSEMBLY OF THE VARIOUS
COMPONENTS. THE DRAWINGS DO NOT INDICATED EXTENSIVE DETAILS. THE CONTRACTOR SHALL HAVE REVIEWED THESE PLANS, SEEN THE SUBJECT PROPERTY AND BE CAPABLE OF EXECUTING THE DETAIL WORK
NECESSARY TO ACHIEVE THE INTENDED RESULT IN A MANNER CONSISTENT WITH QUALITY WORKMANSHIP WITHIN THE REGION. IT IS INCUMBENT UPON THE CONTRACTOR TO REPORT IN WRITING TO THE ARCHITECT OR OWNER
OF THE PROPERTY PRIOR TO SUBMISSION OF THE BID ANY QUESTIONABLE ERROR OR OMISSION IN INTENT OR METHOD OF CONSTRUCTION.
C.
THESE CONTRACT DOCUMENTS WERE PREPARED IN ACCORDANCE WITH THE 2018 INTERNATIONAL RESIDENTIAL CODE NEW JERSEY EDITION AND THE NEW JERSEY STATE UNIFORM CONSTRUCTION CODE AS
AMENDED. THE CONTRACTOR SHALL CONFORM TO THIS AND OTHER APPLICABLE LOCAL, COUNTY, STATE AND FEDERAL CODES, BY LAWS, REGULATIONS, ORDINANCES AND REQUIREMENTS. ALL CONSTRUCTION SHALL
CONFORM TO ACCEPTED GOOD PRACTICE AS BY THE LATEST EDITIONS OF "THE NATIONAL BUILDING CODE," 2018 INTERNATIONAL RESIDENTIAL CODE NEW JERSEY EDITION AND F.H.A MINIMUM PROPERTY STANDARDS. ALL
ARE READILY AVAILABLE TO THE TRADES.
D.
THESE CONTRACT DOCUMENTS WERE PREPARED TO COMPLY WITH THE 2018 IECC
E.
SLEEPING ROOM WINDOWS SHALL COMPLY WITH THE REQUIREMENTS OF THE 2018 INTERNATIONAL RESIDENTIAL CODE NEW JERSEY EDITION SECTION R310, EMERGENCY ESCAPE AND RESCUE OPENINGS.
F.
NO BASEMENT SPACES ARE INTENDED FOR RESIDENTIAL OCCUPANCY.
G.
IT IS UNDERSTOOD THAT THE ARCHITECT WILL NOT BE RESPONSIBLE FOR ANY ADDITIONAL COST BECAUSE OF CONDITIONS UNCOVERED DURING CONSTRUCTION. THESE DRAWINGS ARE PREPARED BASED UPON
H
HA
HD
HDR
HDW
HM
HVAC
HT
HORZ
HIGH
HANDICAP ACCESSIBLE
HEAD
HEADER
HARDWARE
HOLLOW METAL
HEATING VENTILATION & AIR
CONDITIONING
HEIGHT
HORIZONTAL
IN
INSUL
INT
INCH
INSULATION
INTERIOR
JT
JST
JOINT
JOISTS
L
LF
LINO
LT
LONG
LINEAL FEET
LINOLEUM
LIGHT
MAT'L
MAX
MECH
MIL
MIN
MIR
MO
MATERIAL
MAXIMUM
MECHANICAL
MILLIMETER
MINIMUM
MIRRORED
MASONRY OPENING
N
N/A
NE
NIC
NO
NOM
NTS
NW
NORTH
NOT APPLICABLE
NORTHEAST
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
NORTHWEST
OC
OPN'G
OPP
OSB
ON CENTER
OPENING
OPPOSITE
ORIENTED STRAND BOARD
PLYWOOD
PAINT
QC
QUALITY CONTROL
REF
REG'D
RFTS
RM
RO
REFERENCE
REQUIRED
RAFTERS
ROOM
ROUGH OPENING
S
SCHD
SE
SECT
SF
SIM
SHR
SS
STL
STRUC
SUSP
SW
SYM
SOUTH
SCHEDULED
SOUTHEAST
SECTION
SQUARE FEET
SIMILAR
SHEAR
STAINLESS STEEL
STEEL
STRUCTURE
SUSPENDED
SOUTHWEST
SYMMETRICAL
T&G
THK
TO
TOF
TOS
TYP
TONGUE AND GROOVE
THICK
TOP OF
TOP OF FOOTING
TOP OF STEEL
TYPICAL
UNO
UNLESS NOTED OTHERWISE
VERT
VFY
VOL
VTR
VERTICAL
VERIFY
VOLUME
VENT THROUGH ROOF
W
W/
W/O
WC
WD
WIN
WIC
WT
WWM
WEST/WIDE
WITH
WITHOUT
WATER CLOSET
WOOD
WINDOW
WALK IN CLOSET
WEIGHT
WOVEN/WELDED WIRE MESH
S.
M.
U.
V.
N.
O.
MODIFICATIONS TO THESE PLANS BY THE CONTRACTOR SHALL NOT BE MADE WITHOUT WRITTEN PERMISSION BY THE ARCHITECT OR OWNER OF THE PROPERTY. A COPY OF SUCH CHANGES SHALL BE FILED WITH
THE OWNER AND CONTRACTOR SHALL HOLD HARMLESS THE ARCHITECT FROM AND AGAINST ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES INCLUDING LEGAL FEES ARISING OUT OF OR RESULTING FROM THE
SHEET INDEX
PERFORMANCE OF THE WORK BY THE CONTRACTOR.
J.
CONSTRUCTION SHOWN AND SPECIFIED SHALL CONFORM TO ALL APPLICABLE BUILDING CODES. WHERE LOCAL CODES CONFLICT WITH THESE DRAWINGS, CODE REQUIREMENTS TAKE PRECEDENCE.
K.
IT IS ASSUMED THAT WHEN A BUILDING PERMIT IS ISSUED BY THE BUILDING INSPECTOR, THAT HE/SHE HAS THOROUGHLY EXAMINED THE DRAWINGS AND SPECIFICATIONS ACCORDING TO THE 2018 INTERNATIONAL
RESIDENTIAL CODE NEW JERSEY EDITION REQUIREMENTS. ANY CHANGES ADDITIONS ETC., MADE BY ANY PARTY OTHER THAN THE ARCHITECT DURING CONSTRUCTION SHALL BR THE RESPONSIBILITY OF THE PERSON MAKING
SUCH CHANGES.
L.
M.
THE FOLLOWING, UNLESS PROVIDED FOR IN THESE DRAWINGS, ARE TO BE FURNISHED BY THE OWNER.
1.
SITE GRADING, DRAINAGE, AND UTILITIES.
2.
SELECTION OF INTERIOR MATERIAL FINISHES, CABINETRY AND HARDWARE.
3.
STANDARD OF QUALITY AND ACCEPTABLE MANUFACTURERS FOR PREFABRICATED ITEMS.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL THE PLANS, DIMENSIONS AND SITE CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION, DO NOT SCALE DRAWINGS. ALL WRITTEN DIMENSIONS SHALL GOVERN.
NOTIFY ARCHITECT AND OR OWNER OF ALL DEVIATIONS TO THE PLAN BEFORE PROCEEDING WITH THE WORK.
N.
CONTRACTOR OR OWNER SHALL OBTAIN ALL NECESSARY PERMITS FROM THE TOWN AND LOCAL AUTHORITIES.
O.
ALL CONTRACTOR TO PROVIDE ALL NECESSARY BARRICADE AND SAFETY PRECAUTIONS AND TO STRICTLY ADHERE TO LOCAL, STATE AND O.S.H.A SAFETY REQUIREMENTS.
P.
ALL CONTRACTOR SHALL MAINTAIN CONTRACTOR'S LIABILITY, PROPERTY DAMAGE INSURANCE AND WORKMAN'S COMPENSATIONS INSURANCE TO FULLY PROTECT THE CONTRACTOR AND OWNER AGAINST ANY
CLAIMS. THE CONTRACTOR SHALL FURNISH TO THE OWNER CERTIFICATE THAT THESE POLICIES ARE IN EFFECT.
Q.
R.
S.
ALL CONTRACTORS AND SUBCONTRACTORS ARE RESPONSIBLE FOR ADHERING TO THE REQUIREMENTS AS SPELLED OUT IN THESE NOTES. ALL PARTIES MUST CAREFULLY STUDY ALL NOTES FOR ITEMS WHICH MAY
PERTAIN TO THEIR TRADES. FAILURE TO READ THE NOTES DOES NOT PERMIT THE CONTRACTOR TO DEVIATE FROM THEIR REQUIREMENTS. THESE SPECIFICATIONS ARE INTENDED TO SUPPLEMENT THE WORKING DRAWINGS,
WHICH TOGETHER ARE TO BE USED FOR PERFORMING THE WORK. WHERE THE SPECIFICATIONS DISAGREE WITH THE DRAWINGS, THE DRAWINGS SHALL SUPERCEDE.
T.
ALL CONTRACTORS AND SUBCONTRACTORS ON THIS PROJECT SHALL BE RESPONSIBLE FOR THE PROPER PERFORMANCE OF THEIR WORK, COORDINATION WITH OTHER TRADES, METHODS, SAFETY AND SECURITY ON
THE JOB SITE. THE ARCHITECT OFFICE AND ITS AGENTS AND EMPLOYEES ARE NOT RESPONSIBLE OR LIABLE FOR THE ABOVE AND SHALL BE HELD HARMLESS AND INDEMNIFIED BY ALL CONTRACTORS AND SUBCONTRACTORS
FROM ANY AND ALL CLAIMS, LOSSES, SUITS AND LEGAL ACTION WHATSOEVER ARISING FROM THE PERFORMANCE OF THE WORK ON THIS PROJECT.
U.
ALL MATERIALS AND EQUIPMENT SHALL BE APPROVED FOR USE AS REQUIRED BY GOVERNING MUNICIPAL, STATE AND OR FEDERAL AGENCIES AND SHALL BEAR ALL REQUIRED CONDITIONS. ALL EXISTING
CONDITIONS AND DIMENSIONS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR SHALL REPORT IN WRITING ANY DISCREPANCIES TO THE ARCHITECT IMMEDIATELY UPON
DISCOVERY OF SUCH CONDITIONS.
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
01 OF 13
COVER SHEET AND SHEET INDEX
02 OF 13
GENERAL AND TECHNICAL NOTES
FOR
03 OF 13
LEGENDS AND ARCHITECTURAL DETAILS
04 OF 13
ARCHITECTURAL DETAILS
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
05 OF 13
COUNTY'S SURVEY PLAT AND EXISTING BUILDING LAYOUT
06 OF 13
EXISTING FIRST FLOOR ARCHITECTURAL PLAN
07 OF 13
EXISTING SECOND FLOOR ARCHITECTURAL PLAN
08 OF 13
EXISTING BASEMENT FLOOR ARCHITECTURAL PLAN
09 OF 13
PROPOSED FIRST FLOOR ARCHITECTURAL PLAN
THE ARCHITECT HAS PREPARED THESE DRAWINGS BASED ON DISCUSSIONS WITH THE OWNERS AND ARCHITECT'S OWN KNOWLEDGE OF CONSTRUCTION TECHNIQUES AND BUILDING CODES. IT IS INCUMBENT UPON
THE OWNER TO REVIEW THE FINAL PLANS TO INSURE HIS INTENT HAS BEEN MET AND TO NOTIFY THE ARCHITECT IMMEDIATELY (BEFORE COMMENCING CONSTRUCTION) OF ANY CHANGES HE DESIRES.
PROJECT:
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
DWG. No. DESCRIPTION
THE CONTRACTOR SHALL TAKE NECESSARY STEPS TO PROTECT THE WORK AND ALL MATERIALS AND SUPPLIES ON THE CONSTRUCTION SITE AGAINST LOSS OR DAMAGE FROM FIRE, VANDALISM AND MISCHIEF AT
ALL TIMES.
PLAN REVIEW INFO:
W.
THE CONSTRUCTION OFFICIAL. ANY MODIFICATIONS MADE WITHOUT THE PRIOR WRITTEN PERMISSION WILL BE THE SOLE RESPONSIBILITY OF THE PARTY ENACTING SUCH MODIFICATIONS.
I.
CONSULTANTS:
T.
INFORMATION SUPPLIED BY THE OWNER INCLUDING DRAWINGS, SURVEY ETC.
H.
ARCHITECTURE
INTERIOR DESIGN
R.
L.
F.
PLYWD
PT
Q.
J.
E.
DRAWINGS SHALL NOT BE PROTOTYPED WITHOUT AUTHORIZATION FROM ARCHITECT OR OWNER OF THE PROPERTY. UNLESS STATED SPECIFICALLY BY LETTER, THESE DRAWINGS MAY BE USED TO CONDUCT ONLY ONE OF THE
GAUGE
GALVANIZED
GYPSUM
I.
D.
GENERAL CONDITIONS:
GA
GALV
GYP
H.
B.
346 CENTRE ST, TRENTON,
MERCER COUNTY N.J 08611
P.
G.
@
AFF
AL
APPR
10 OF 13
PROPOSED SECOND FLOOR ARCHITECTURAL PLAN
11 OF 13
PROPOSED BASEMENT FLOOR ARCHITECTURAL PLAN
12 OF 13
13 OF 13
SHEET TITLE:
COVER SHEET
AND
SHEET INDEX
DATE:-
PROJECT NO.
01
EXISTING ELEVATIONS WITH PROPOSED DETAILS
SCALE:
AS NOTED
SHEET NO.
EXISTING ELEVATIONS WITH PROPOSED DETAILS
DRAWN:
MI
CHECKED:
SJ & AG
A-1
DWG. NO.
01 OF 13
REVISIONS
GENERAL NOTES:
CONCRETE NOTES:
THE FOLLOWING SPECIFICATIONS ARE OUTLINE OF MINIMUM
REQUIREMENTS AND THEIR
1.
ALL CONCRETE CONSTRUCTION SHALL CONFORM TO THE LATEST A.C.I CODE. AND BE DETAILED,
APPLICATION. MANUFACTURER SPECIFICATIONS AND LOCAL CODE REQUIREMENTS, WHEN IN EXCESS OF
REINFORCED, AND INSTALLED PER REQUIRMENTS OF ACI 318, ACI 301, AND ACI 302. AIR ENTRAINED
MINIMUM SPECIFICATION SHALL CONTROL.
CONCRETE SHALL BE USED FOR GARAGE SLABS AND ALL EXTERIOR SLABS.
1.
2.
THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING AND PROPOSED DIMENSIONS AND
2. FOUNDATIONS ARE DESIGNED FOR A GROSS SOIL-BREAKING CAPACITY OF 2000 PSF ±
CONDITIONS AT THE JOB SITE PRIOR TO BEGINNING THIS PROJECT AND REPORT ANY DISCREPANCIES TO
SHOULD ACTUAL CAPACITY BE LESS, NOTIFY ARCHITECT IMMEDIATELY AND FOUNDATIONS WILL BE
THE ARCHITECT BEFORE STARTING THE WORK. THE FAILURE TO DO SO WILL IN NO WAY RELIEVE THE
CONTRACTOR OF FURNISHING ALL MATERIALS AND PEFORMING ALL WORK REQUIRED FOR COMPLETION OF
REDESIGNED.
3.
3. FOUNDATIONS SHALL REST ON UNDISTURBED SOIL OR COMPACTED GRAVEL BACK FILL,
THE WORK IN CONFORMANCE WITH THE DRAWINGS OR AS REQUIRED BY SITE CONDITIONS. CONTRACTORS
BELOW THE MINIMUM FROST DEPTH.
SHALL ASSUME RESPONSIBLE FOR ERRORS THAT ARE NOT REPORTED.
4.
2.
THE
CONTRACTOR
SHALL
BE
RESPONSIBLE
TO
CHECK
AND
COORDINATE
DIMENSIONS,
4. EXCAVATIONS FOR FOOTINGS SHALL BE NEAT
IMMEDIATELY AFTER EXCAVATION.
CLEARANCES, ETC. WITH THE WORK OF ALL OTHER TRADES.
5.
3.
DENSITY.
ALL SUBSTITUTIONS AND/OR CHANGES AFFECTING THE DESIGN OF THIS STRUCTURE SHALL BE
AND FOOTINGS SHALL BE POURED
5. ALL FILL WITHIN CONFINES OF BUILDING SHALL BE COMPACTED TO 95% OF MAXIMUM
SUBJECT TO ARCHITECT AND ENGINEER APPROVAL.
6.
4.
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH NATIONAL, STATE AND LOCAL
CODES.
28 DAYS (EXCEPT AS OTHERWISE NOTED). FLOOR SLABS SHALL BE 4000 PSI STRENGTH.
7.
5.
ALL CONCRETE SHALL BE CURED IN ACCORDANCE WITH THE LATEST SPECIFICATIONS OF A.C.I CODE.
CONTRACTOR SHALL COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS IN FLOORS, WALLS
6. ALL CONCRETE SHALL HAVE A MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 3000 PSI @
7. NO CONCRETE IS TO BE POURED WHEN THE TEMPERATURE IS 40 DEGREES f. AND FALLING.
AND ROOFS CONSTRUCTIONS AS REQUIRED WHETHER SHOWN OR NOT ON THE ARCHITECTURAL AND/OR
8.
8. ALL REINFORCING SHALL MEET THE REQUIRMENTS OF ASTM 615, FS = 24,000 PSI.
OTHER DRAWINGS AND PROVIDE LINTELS OR HEADERS AS REQUIRED.
9.
9. ALL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 SPECIFICATIONS AND SHALL BE
6.
PLACED IN UPPER 1/3 OF THE SLAB.
WHERE ALUMINUM IS ADJACENT TO STEEL, PROVIDE ADEQUATE BARRIER TO PREVENT OXIDATION
OF ALUMINUM. TYPICAL FOR OTHER DISSIMILAR METALS.
10.
7.
CHASES, ETC., TO BE SET IN CONCRETE AS REQUIRED FOR THE WORK OF THE TRADES AND VERIFY THE
ALL ACCESSORIES NOT SHOWN ON THE DRAWINGS OR SPECIFICALLY CALLED FOR SUCH AS
BLOCKING, BULKHEADS, CATS, FASTENERS, MISCELLANNEOUS TRIM, ETC., REQUIRED AND NECESSARY
10. THE GENERAL CONTRACTOR SHALL INSTALL ALL ANCHORS, PIPE SLEEVES, INSERTS,
LOCATIONS OF THE SAME BEFORE PROCEEDING WITH THE CONCRETE WORK.
AND CONSIDERED GENERAL PRACTICE FOR HOME CONSTRUCTION SHALL BE CONSIDERED PART OF THE
MASONRY NOTES:
BUILDING CONTRACT.
8.
WHEN THE PROJECT IS AN ADDITION OR REMODELING JOB, THE CONTRACTOR SHALL FAMILIARIZE
HIMSELF WITH EXISTING CONDITIONS (TRIM, TEXTURES, MATERIALS, METHODS OF CONSTRUCTION, ETC.)
AND MATCH EXISTING UNLESS OTHERWISE NOTED.
9.
THE CONTRACTOR IS RESPONSIBLE FOR THE SAFETY OF THE EXISTING STRUCTURE. THE
CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION REQUIRED TO COMPLETE THE WORK WHETHER
SHOWN ON THE DRAWINGS OR NOT INCLUDING, BUT NOT LIMITED TO PARTITIONS, FLOORS AND FLOOR
COVERINGS, CEILINGS, ROOF AND/OR STRUCTURE, LIGHTING, ELECTRICAL, PLUMBING, HVAC, ETC., AS
REQUIRED. REPLACE AND RELOCATED AS REQUIRED.
10.
CONTRACTOR SHALL INSURE COMPATIBILITY OF THE BUILDING WITH ALL SITE REQUIREMENTS.
11.
THE CONTRACTOR SHALL FURNISH OWNERS WITH INSURANCE CERTIFICATION AND WAIVERS OF
MECHANICS LIENS BEFORE PROCEEDING WITH THE WORK.
12.
ALL MATERIALS, WORK AND EQUIPMENT AND ITS INSTALLATION BY THE CONTRACTOR SHALL BE
1.
ALL MASONRY WORK SHALL CONFORM TO THE ANSI A-41.2 REQUIREMENTS FOR MASONRY
16.
ALL ENGINEERED LUMBER SHALL MEET
ENGINEERED LUMBER" OR EQUAL
THE
REQUIREMENTS OF
"GEORGIA-PACIFIC
17.
E: 2,000,000 PSI
PRE-FAB ENGINEERED LUMBER FOR FLOOR AND ROOF
PERFORMANCE WITH A MAXIMUM LIVE LOAD DEFLECTION LIMIT OF L/480 BASED UPON "GEORGIA
PACIFIC ENGINEERED LUMBER".
18.
MINIMUM THICKNESS OF FLOOR SHEATHING SHALL BE 3/4" TONGUE AND GROOVE
PLYWOOD, GLUED AND SCREWED TO FLOOR JOISTS IN ACCORDANCE WITH APA REQUIREMENTS.
19.
THE ASSEMBLY AND INSTALLATION OF FRAMING DETAILS SHALL MEET THE MINIMUM
REQUIREMENTS OF "FLOOR DETAILS" F1 - F20 "CANTILEVER DETAILS" C1-C5, AND "ROOF DETAILS" R1 R11, AS ILLUSTRATED PER "GEORGIA PACIFIC RESIDENTIAL FLOOR AND ROOF SYSTEM PRODUCT
GUIDE". CURRENT EDITION.
20.
PROVIDE SIMPSON STRONG TIE, "SST" METAL COLUMN TO BEAM CONNECTORS AT ALL
TO FOUNDATION OR LOWER SUPPORT BEAM. PROVIDE SOLID BLOCKING UNDER ALL COLUMNS AT
FLOOR.
21.
CONNECT ALL ROOF RAFTERS TO RIDGE MEMBERS WITH SIMPSON STRONG TIE, "SST"-LSSU",
SLOPING JOIST CONNECTORS. SELECT SIZE OF CONNECTOR TO MATCH SIZE OF RAFTER OR RAFTER
BEAM.
22.
CONNECT ALL ROOF RAFTERS TO TOP PLATE OF WALLS. USE A MINIMUM OF SIMPSON
STRONG TIE, "SST-HI" AT EACH ROOF RAFTER UNLESS NOTED OTHERWISE.
23.
PROVIDE FOR ALL FIRE STOPPING IN WALLS AND FLOORS AS REQUIRED BY BUILDING CODE.
24.
PROVIDE TERMITE SHIELDS AND PRESSURE-TREATED SILL PLATES ON ALL CONCRETE AND
25.
MINIMUM OF (2) 3/8" DIA. BOLTS @ 32" O.C OR EQUIVALENT "HILTI" SHOTS.
WOOD FRAMING SIZES, VERTICAL FRAMING, HORIZONTAL FRAMING, FIRE STOPS, DRAFT
STOPS, ANCHORS, FURRING AND CONNECTORS NOT SHOWN ON DOCUMENTS SHALL BE PER LOCAL
BEARING BLOCK.
BUILDING CODE MINIMUM REQUIREMENTS.
3.
27.
ALL WOOD IN CONTACT WITH CONCRETE, MASONRY OR EXPOSED TO WEATHER SHALL BE
OR EQUAL) AT ALL MORTAR JOINTS, 16" ON CENTER VERTICALLY, UNLESS NOTED OTHERWISE.
TREATED LUMBER OR REGULAR LUMBER ON MASTIC BEDDING.
4.
MASONRY REINFORCEMENT SHALL MEET THE REQUIREMENTS OF ASTM A-615, FS = 24,000 PSI.
28.
5.
ALL CONCRETE BLOCK BELOW GRADE SHALL BE REGULAR UNITS (UNLESS OTHERWISE NOTED).
AGENCY. SURFACE DRY: TO 18% MAXIMUM MOISTURE CONTENT.
6.
NO BACK FILL SHALL BE PLACED AGAINST ANY FOUNDATION WALL UNTIL WALLS ARE PROPERLY
29.
ALL LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED TESTING
ALL TREATED LUMBER SHOULD BE "ACQ" ALKALINE COPPER QUATERNARY LUMBER AND ALL
BRACED OR FLOORS ARE ERECTED AND ANCHORED IN PLACE.
FASTENERS SHOULD BE HOT DIPPED GALVANIZED AND NO ALUMINUM FLASHING SHOULD NOT BE IN
7.
DIRECT CONTACT WITH THE TREATED MATERIAL, USE EPDM OR A POLY MATERIAL TO CREATED A
FRAMING NOTES:
BUILDING DEPARTMENT DATA
THE FOLLOWING NOTES ARE SUGGESTED MINIMUM REQUIREMENTS ONLY.
THESE DRAWINGS ARE PROPERTY OF THE ARCHITECT AND THEIR USE IS GRANTED (CONTINGENT
SPECIFICATIONS HEREIN, WHERE MORE STRINGENT SHALL BE COMPLIED WITH.
1.
PROVIDE PURLINS AT MID HEIGHT OF ALL WALLS.
UPON PAYMENT OF THE REQUIRED FEE TO THE ARCHITECT) FOR THE OWNER / BUILDERS USE IN THE
14.
2.
ALL JOISTS AND RAFTERS SHALL BE ALIGNED OVER STUDS BELOW.
CONSTRUCTION OF A SINGLE STRUCTURE. ANY USED OR REUSE OF THESE DOCUMENTS WITHOUT
AROUND THE CONSTRUCTION AREA. ADEQUATE BARRIERS SHALL BE PROVIDED TO EXERCISE CONTROL OF
3.
ALL HEADERS SHALL BE 3-2x10'S WITH DOUBLE 1/2" PLYWOOD FLITCH PLATE UNLESS
THE PRIOR WRITTEN PERMISSION OF THE ARCHITECT IS FORBIDDEN. THE ARCHITECT MAINTAINING
SAFE INGRESS AND EGRESS OF CONSTRUCTION AREA.
OTHERWISE NOTED.
HIS COPYRIGHT OF THESE DOCUMENTS IN CONFORMANCE WITH ALL APPLICABLE LAWS OF THE
15.
4.
UNITED STATES OF AMERICA.
13.
CONTRACTOR SHALL INSTALL ALL MANUFACTURED ITEMS. MATERIALS AND EQUIPMENT IN STRICT
ACCORDANCE
WITH
THE
MANUFACTURERS
RECOMMENDED
SPECIFICATIONS,
EXCEPT
THE
THE CONTRACTOR SHALL PROVIDE PROTECTION FOR OWNER AND THE GENERAL PUBLIC IN AND
WORK NOT IDENTIFIED IN A CERTAIN LOCATION ON A DRAWING BUT RESPONSIBLY IMPLIED TO BE
FRAMER TO INSTALL DOUBLE FLOOR JOISTS UNDER PARTITION WALL PARALLEL TO JOIST
SIMILAR TO THAT SHOWN IN A CORRESPONDING LOCATION SHALL BE CONSIDERED TO BE PART OF THIS
DIRECTION.
CONTRACT.
5.
16.
ITEMS IDENTIFIED AS "EXISTING" ARE EXISTING TO REMAIN (U.N.O)
PROVIDE (2) ROWS FOR ALL SPANS OVER 16'-0" SIMPSON STRONG TIE, "SST" TB27 METAL "X" BRIDGING.
2021 INTERNATIONAL MECHANICAL CODE
17.
EXISTING ITEMS TO REMAIN THAT ARE DAMAGED OR DISTURBED AS A RESULT OF WORK
6.
2020 NATIONAL STANDARD PLUMBING CODE
PROVIDE A MINIMUM OF (1) ROW OF "X" BRIDGING AT ALL FLOOR AND ROOF JOIST SPANS.
ALL EXTERIOR CORNERS INSIDE AND OUTSIDE CORNERS SHALL BE MINIMUM BRACED WITH 1/2"
2021 NATIONAL ELECTRICAL CODE
THE ARCHITECT AND WITHOUT ADDITIONAL COST TO THE OWNER.
(OPTION-APPROVED DIAGONAL CORNER BRACES BOTH DIRECTIONS AT ALL CORNERS).
2021 INTERNATIONAL FUEL GAS CODE
18.
7.
INTERNATIONAL ENERGY CONSERVATION CODE 2021 - RESIDENTIAL
THE CONTRACTOR SHALL LEGALLY DISPOSE OFF ALL UNUSED MATERIAL AND DEBRIS OFF THE
ALL COLUMNS OR SOLID FRAMING SHALL EXTEND DOWN TO FOOTINGS DESIGNED TO CARRY
IMPORTANCE FACTOR "STANDARD - RESIDENTIAL" UNLESS OTHERWISE NOTED
LOAD.
8.
CONDITION CODES AND MANUFACTURER'S RECOMMENDATIONS.
THAN 10'-0".
ALL WORK TO BE DONE IN ACCORDANCE WITH THE FLOOR PLANS, ELEVATIONS, SECTIONS, DETAILS
20.
9.
AND NOTES SHEET PREPARED BY THE ARCHITECT AND THE WOOD FRAME CONSTRUCTION MANUAL
PROVIDE DOUBLE 2x8 STRONG BACK AT MID SPAN FOR CEILING JOISTS WITH SPAN GREATER
PROVIDE COLLAR TIES AT UPPER 1/3 OF VERTICAL DISTANCE BETWEEN RIDGE BOARD AND
PROTECTION ASSOCIATION AND ALL GOVERNING CODES AND ADMINISTRATION BY LOCAL BUILDING
CEILING JOIST AT 16" O.C. MAXIMUM.
(WFCM) 115 MPH, EXPOSURE B GUIDE AS PUBLISHED BY
OFFICIALS AND SHALL BE CONSIDERED PART OF THE CONSTRUCTION DOCUMENTS.
10.
ASSOCIATION, AMERICAN WOOD COUNCIL IN COOPERATION WITH THE INTERNATIONAL CODE
21.
PROVIDE ICE DAM PROTECTION AT ALL ROOF PENETRATIONS.
RAFTERS.
22.
PROVIDE JOIST HANGERS AT HEADERS AND TAILS OF ALL FRAMING CONNECTIONS.
11.
ROOF DECKING SHALL BE 5/8" CDX PLYWOOD MINIMUM UNLESS NOTED OTHERWISE.
23.
RANDON TESTING AND CORRECTIVE MEASURES (IF ANY) ARE THE RESPONSIBILITY OF THE OWNER.
12.
ALL CEILING JOIST AND RAFTER BRACING TO BEAR ON LOAD-BEARING WALLS DESIGNED TO
HIP VALLEY RAFTERS AND RIDGE BOARDS SHALL BE (1) 2x OR (1) 1-3/4" LVL SIZE LARGER THAN
THE AMERICAN
FOREST
COUNCIL.
THE BUILDER SHALL COORDINATE AND REVIEW ALL DESIGN DOCUMENTATION AND BRING ANY
24.
ALL DIMENSIONS SHOULD BE READ OR CALCULATED AND NEVER SCALED.
CARRY LOAD THROUGH ALL LEVELS AND TERMINATE AT FIRST FLOOR AND BE SUPPORTED BY STEEL
25.
ALL INTERIOR AND EXTERIOR FINISHES AND COLORS ARE THE RESPONSIBILTY OF THE OWNER
BEAM OR FOOTING DESIGNED TO CARRY LOAD.
PROCEEDING WITH THE WORK.
13.
26.
NOTED.
THE GENERAL CONTRACTOR IS RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING
ALL EXTERIOR FRAMED WALL DIMENSIONS ARE BASED ON 2x6 STUDS UNLESS OTHERWISE
ALL SAFETY PRECAUTIONS AND PROGRAMS NECESSARY FOR THE COMPLETION OF THE WORK.
14.
27.
ALL BATHROOMS WATERPROOF WALLS ARE 2x8 OR 2x12 STUDS U.N.O.
THE ARCHITECT AND/OR ENGINEER SHALL HAVE NO RESPONSIBILITY FOR THE SAFETY OF ANY
ALL INTERIOR FRAMED WALL DIMENSIONS ARE ON 2x4 STUDS UNLESS OTHERWISE NOTED AND
WORKMAN OR CONTRACTOR. THIS RESPONSIBILITY SHALL BE THAT OF EACH WORKMAN AND/OR
15.
CONTRACTOR.
FOLLOWING CRITERIA:
JOIST/RAFTER SIZES AND SPACING ARE MINIMUM REQUIREMENTS AND ARE BASED UPON THE
USE GROUP CLASSIFICATION
R-5
CONSTRUCTION TYPE
5-B
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
PAPER
DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT FOR RESOLUTION IN WRITING BEFORE
AND SHALL COMPLY WITH CODES FOR FLAME SPREAD RATING AND SMOKE GENERATION FACTOR.
PLAN REVIEW INFO:
PROJECT:
PREMISES.
19.
PROVIDE CONTROL OR EXPANSION JOINTS IN ALL CONSTRUCTION AS REQUIRED BY THE JOB
ALL ELECTRICAL WORK SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE, THE FIRE
CONSULTANTS:
2021 INTERNATIONAL RESIDENTIAL CODE (NEW JERSEY EDITION)
CDX PLYWOOD. NAILING SCHEDULING SHALL BE 8d COMMONS AT 12" O.C. AT ALL INTERMEDIATE STUDS
PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED AND/OR REPLACED TO THE SATISFACTION OF
ARCHITECTURE
INTERIOR DESIGN
BOLT ALL 2x4, 2X6, 2x8 AND 2x12 WOOD PLATES AT TOP FLANGE OF STEEL BEAMS WITH A
SEPARATION.
CODES AND CURRENT ORDINACES.
AUGUSTUS GEHRY
ARCHITECT
CONCRETE MASONRY UNITS.
GALVANIZED OR BE FINISHED WITH GALVANIZED PAINT AND FINISH PAINT.
IN COMPLIANCE WITH THE 2018 INTERNATIONAL ONE AND TWO FAMILY DWELLING CODE AND ALL LOCAL
ARCHITECT:
INTERSECTIONS OF BEAMS AND COLUMNS. ADDITIONAL USE SAME TO CONNECT BASE OF COLUMNS
2.
STEEL LINTELS FOR BRICK/STONE SHALL MEET THE REQUIREMENTS OF ASTM A-36 AND BE
DESCRIPTION
JOISTS SHALL BE SYSTEM
26.
MASONRY WALLS SHALL HAVE GALVANIZED TRUSS-TYPE REINFORCEMENT (9-GA. DUR-O-WALL
DATE
Fb: 2,800 PSI
CONSTRUCTION.
ALL CONCRETE MASONRY UNITS SHALL MEET THE REQUIREMENT OF ASTM C-90 HOLLOW LOAD
NO.
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
FOR
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
SHEET TITLE:
GENERAL
AND
TECHNICAL
NOTES
SPECIES: HEM-FIR, NO.2 OR BETTER
Fb: 1,200 PSI
E: 1,200,000 PSI
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
CHECKED:
SJ & AG
A-2
DWG. NO.
02 OF 13
REVISIONS
NO.
ZONING INFORMATION
346 CENTER STREET TRENTON, MERCER COUNTY N.J 08611
GOVERNING ZONING CODE:
CITY OF TRENTON, MERCER COUNTY, NEW JERSEY ZONING ORDINANCE
BUILDING CODE:
NJ UNIFORM CONSTRUCTION CODE (UCC), N.J.A.C 5:23-2021 EDITION
EXISTING BUILDING:
INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2021
STRUCTURAL:
INTERNATIONAL BUILDING CODE (IBC) 2021
01
ADDRESS:
02
BOARD AND FILE NUMBERS:
PLUMBING:
NATIONAL STANDARD PLUMBING CODE 2021
03
FOLIO NUMBER(S):
MECHANICAL:
INTERNATIONAL MECHANICAL CODE (IMC) 2021
ELECTRICAL:
NATIONAL ELECTRICAL CODE (NEC) 2020
04
YEAR CONSTRUCTED:
ACCESSIBILITY:
ICC/ANSI A- ACCESSIBLE AND USABLE BUILDING AND FACILITIES
05
BASE FLOOD ELEVATION:
FIRE PROTECTION:
NEW JERSEY UNIFORM FIRE CODE (N.J.A.C 5:70) -2021 EDITION
06
ADJUSTED GRADE (FLOOD + GRADE/2):
07
LOT WIDTH (FT):
08
MINIMUM UNIT SIZE (SF):
09
EXISTING USE:
8.00'
500.00
EXISTING USE:
MAXIMUM
HEIGHT:
11
NUMBER OF STORIES:
RH1
GRADE VALUE IN NGVD:
3.75'
LOT AREA (SF):
5.87'
50.00'
10
ZONING DISTRICT:
50'-0"
MINIMUM LOT WIDTH:
13
MAXIMUM BUILDING COVERAGE:
LOT DEPTH (FT):
MATERIALS:
AVERAGE UNIT SIZE (SF):
917.00
PROPOSED USE:
SINGLE FAMILY HOME:
EXISTING
PROPOSED
28'-0" +/-
28'-0" +/-
02
02
14
MAXIMUM IMPERVIOUS COVERAGE:
831 SF / 4500 SF
N/A
ARCHITECT:
7,825.00
SYMBOL LEGENDS:
12
DEFICIENCIES
INSULATION
BLANKET
CONCRETE
PRE CAST
GRAVEL OR
CRUSHED STONE
CEMENT MORTAR
PLASTER
N/A
FINISH SCHEDULE
123
BATH ROOM
ROOM NUMBER
ROOM NAME
68.3% (5,346 SF) +/GLASS:
LARGE SCALE
12
15
NUMBER OF UNITS RESIDENTIAL:
N/A
N/A
16
NUMBER OF UNITS HOTEL:
N/A
N/A
INSULATION
RIGID
EARTH
SOLID CONCRETE
MASS UNIT
TILE
WALL
CONSTRUCTION
SQUARE FOOTAGE BY USE:
18
OCCUPANCY LOAD:
N/A
N/A
MARBLE
SETBACKS
N/A
REQUIRED
STEEL
SMALL SCALE
STEEL
LARGE SCALE
PLYWOOD
BUILDING / PARTIAL
& DETAIL SECTION
SYMBOL
3
A-3
EXTERIOR & INTERIOR
ELEVATION SYMBOL
DETAIL NUBER
CONSTRUCTION
DETAIL SYMBOL/
SHEET NUMBER
DETAILED AREA
SHEET METAL
PROPOSED
-2.0 FT (EN)
-2.0 FT (EN)
MINIMUM INTERIOR SIDE YARD:
N/A
1.1 FT
1.1 FT
21
MINIMUM CORNER SIDE YARD:
0-5 FT BUILD TO ZONE
-2.0 FT (EN)
-2.0 FT (EN)
22
MINIMUM CORNER SIDE YARD PERCENTAGE:
40%
45% +/-
45% +/-
23
REAR SETBACK:
20'-0"
14.6 FT +/- (EN)
14.6 FT +/- (EN)
REQUIRED
EXISTING
PROPOSED
20
PARKING
24
PARKING DISTRICT No.1
25
TOTAL No. OF PARKING SPACES:
26
PARKING SPACE DIMENSIONS:
27
PARKING SPACE CONFIGURATION (45°, 60°, 90°
PARALLEL):
90°
28
ADA SPACES:
02
29
TANDEM SPACES:
02
30
DRIVE AISLE WIDTH:
31
VALET DROP OFF AND PICK UP:
N/A
32
LOADING ZONES AND TRASH COLLECTION
AREAS:
N/A
33
BIKE RACKS:
08
34
IS THIS A CONTRIBUTION BUILDING?
NO
35
LOCATED WITHIN A LOCAL HISTORIC:
NO
7'-6"
ARCHITECTURE
INTERIOR DESIGN
3
A-3
A-3
DETAIL NUBER
SHEET NUMBER
NUMBER OR
LETTER
EL. 0'-0"
FINISH FLOOR
DEFICIENCIES
NOTES
0-5 FT BUILD TO ZONE
MINIMUM FRONT YARD:
A
AUGUSTUS GEHRY
ARCHITECT
DETAIL NUMBER
ELEVATION
SUBTERRANEAN AND PEDESTAL
19
NOTES
LEGEND LETTER/
NUMBER
N/A
EXISTING
WALL TYPE
3
COLUMN REFERENCE
17
12
CONCRETE
18'-1" / 37'-3"
68.3% (5,346 SF) +/-
DOOR NUMBER
DOOR SYMBOL
ROOM NAME
12
DESCRIPTION
CODES:
SINGLE / MULTIFAMILY RESIDENTIAL ZONING DATA SHEET
ITEM #
DATE
WOOD BLOCKING
CONTINUOUS
WOOD BLOCKING
INTERMITTENT
BRICK
LARGE SCALE
WOOD FINISHED
18
LEGEND LETTER/
NUMBER
DRAWING REVISION
3
REVISION
NUMBER
CONSULTANTS:
CONCRETE
MASS UNIT
SCOPE OF WORK
DESIGN OF MULTI-FAMILY RESIDENCE IN EXISTING BUILDING
PLAN REVIEW INFO:
DEFICIENCIES
08
8'-6" x 18'-0"
PROJECT:
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
18'-0"
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
FOR
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
SHEET TITLE:
LEGENDS
AND
ARCHITECTURAL
DETAILS
LOCATION MAP
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
CHECKED:
SJ & AG
A-3
DWG. NO.
03 OF 13
ACCESSIBILITY NARRATIVE & REQUIREMENTS:
THE FOLLOWING SPECIFICATIONS ARE OUTLINE OF MINIMUM REQUIREMENTS AND THEIR
WALLS SCHEDULE
SR. No.
HORIZONTAL SECTION
14.
DESCRIPTION
APPLICATION FOR ACCESSIBILITY NARRATIVE AND REQUIREMENTS PER NEW JERSEY UNIFORM
FIRE
RATING/STC
CONSTRUCTION CODE (NJUCC), WHICH INCLUDES THE INTERNATIONAL BUILDING CODE (IBC) AND
THE INTERNATIONAL RESIDENTIAL CODE (IRC) WITH NJ AMENDMENTS, AND THE FEDERAL FAIR
HOUSING ACT (FHA).
INTERIOR NON-LOAD BEARING WALL
1.
5/8" GYPSUM BOTH SIDES 2x4 WOOD
STUDS, 16" O.C.
01
NON-RATED
FLOORS FOR ACCESSING TO UPPER / SECOND FLOOR ARE GENERALLY EXEMPT FROM STATE OR
FEDERAL REQUIREMENTS TO INSTALL AN ELEVATOR, PROVIDED THEY MEET SPECIFIC SIZE AND
STC 56
31
2"
IN NEW JERSEY, INCLUDING TRENTON, TWO-DWELLING FOR BUILDINGS HAVE ONLY TWO
STRUCTURAL CRITERIA. THE REQUIREMENT FOR ELEVATORS IN RESIDENTIAL BUILDINGS TYPICALLY
APPLIES TO LARGER, MULTI-STORY STRUCTURES DEFINED AS "COVERED MULTIFAMILY DWELLINGS"
UNDER THE FAIR HOUSING ACT OR "LARGE BUILDINGS" UNDER THE NJ UNIFORM CONSTRUCTION
CODE.
ACCESSIBLE ENTRANCE AND ROUTE FOR ALL THE UNITS HAVE AN ACCESSIBLE ENTRANCE AND AN
INTERIOR LOAD BEARING WALL
5/8" GYPSUM BOARD TYPE x BOTH SIDES
2x4 WOOD STUDS, 16" O.C.
02
31
2"
OCF 423
1 HR
UL #
U305
STC
35-39
TENANT / TENANT SEPARATION WALL
8"
03
5/8" TYPICAL x GYPSUM BOARD ON BOTH
SIDES 2x4 STAGGERED WOOD STUDS @
16" O.C. ON SEPARATE PLATES. 3-1/2"
INSULATION BOTH SIDES
1 HR.
WP #
3370
STC
57-60
TYPICAL EXTERIOR WALL
VARIES
5/8" TYPICAL x GYPSUM BOARD ON
INSIDE FACE OF 2x6 WOOD STUDS @ 16"
O.C. W/ 3-1/2" UNFACED INSULATION,
WOOD SHEATHING WITH EXTERIOR
CLADDING OF MASONRY, STUCCO OR
METAL PANEL
04
1
31
2" OR 52"
1
31
2" OR 52"
06
MODIFICATIONS PROHIBITED: THE FIRE DOOR ASSEMBLY MAY NOT BE MODIFIED IN A WAY
THAT VOIDS ITS LABEL; FOR EXAMPLE, SIGNAGE IS LIMITED TO A SMALL PERCENTAGE OF THE DOOR
FACE AND MUST BE ATTACHED WITH ADHESIVE (NO SCREWS OR NAILS).
17.
OPERATION: FIRE
DOORS
MUST
BE
SELF-CLOSING,
AUTOMATIC-CLOSING,
OR
POWER-OPERATED AND MUST LATCH WHEN IN THE CLOSED POSITION.
ARCHITECT:
2.
MEETS THE MINIMUM CLEARANCE REQUIREMENTS OF 40 INCHES IS REQUIRED BETWEEN ALL
AREA, WITHIN 10 FEET OF THE BEDROOM DOORS.
OPPOSING BASE CABINETS, COUNTERTOPS, APPLIANCES, AND WALLS.
3.
STAIRWELLS: IN ENCLOSED STAIRWELLS, IF APPLICABLE.
2.
4.
TYPE: FOR HOMES BUILT OR SIGNIFICANTLY ALTERED AFTER MARCH 1991, THEY MUST BE
EVERY LEVEL: AT LEAST ONE ON EACH FLOOR, INCLUDING BASEMENTS AND HABITABLE
IN/NEAR BEDROOMS: INSIDE EACH BEDROOM AND OUTSIDE EACH SEPARATE SLEEPING
DOOR THAT PROVIDES A MINIMUM CLEAR OPENING WIDTH OF 39 INCHES AND A MINIMUM CLEAR
120V HARDWIRED WITH BATTERY BACKUP; OLDER HOMES MAY USE 10-YEAR SEALED BATTERY UNITS.
HEIGHT OF 76.5 INCHES.
5.
CARBON MONOXIDE (CO) ALARM REQUIREMENTS:
3.
6.
WITHIN 10 FEET OF SLEEPING AREAS: REQUIRED IN THE IMMEDIATE VICINITY OF ALL
UNITS (TYPE A OR TYPE B), THERE ARE NO SPECIFIC MINIMUM WIDTH REQUIREMENTS FOR INTERIOR
SLEEPING AREAS IN ANY DWELLING WITH A FUEL-BURNING APPLIANCE OR ATTACHED GARAGE.
DOORS, EXCEPT FOR THE MINIMUM HEIGHT REQUIREMENT OF 78 INCHES.
7.
4.
APPLIANCE (FURNACE, WATER HEATER, ETC.).
8.
THE NEW JERSEY UNIFORM CONSTRUCTION CODE AND THE REFERENCED ACCESSIBILITY STANDARDS
BACKUP, THOUGH BATTERY-ONLY OR PLUG-IN CORD TYPES ARE ALLOWED IN CERTAIN SITUATIONS
(NJA117.1),
(E.G., OLDER BUILDINGS WITHOUT POWER, OR DURING REPAIRS).
SPECIFIC
DOORS
WITHIN
THE
ACCESSIBLE
ROUTE
COMPLY
WITH
STRICTER
AUGUSTUS GEHRY
ARCHITECT
ARCHITECTURE
INTERIOR DESIGN
FUEL-BURNING APPLIANCES: ALSO REQUIRED IN ANY ROOM CONTAINING A FUEL-BURNING
CLEAR WIDTH INTERIOR DOORS TO MAKE THAT BE AN ACCESSIBLE DWELLING OR TYPE B UNIT UNDER
TYPE: SIMILAR TO SMOKE ALARMS, THEY SHOULD IDEALLY BE HARDWIRED WITH BATTERY
SPRINKLER SYSTEM STATUS (NFPA 13 / 13R / NONE):
CEILING HEIGHT FOR KITCHEN IN EACH DWELLING MUST HAVE A CLEAR CEILING HEIGHT OF
STC 40
6.
EACH KITCHENS MUST BE PROVIDED WITH MECHANICAL VENTILATION THAT EXHAUSTS AIR
1 HR.
WP #
3240
STC
50-54
1.
IN NEW JERSEY AND TRENTON CITY, AUTOMATIC FIRE SPRINKLER SYSTEMS ARE GENERALLY
NOT MANDATORY FOR STANDARD NEWLY CONSTRUCTED ONE- AND TWO-FAMILY DWELLING UNITS,
BUT THEY ARE REQUIRED IF SPECIFIC CONDITIONS REGARDING BUILDING HEIGHT OR AREA ARE MET.
FIRE-RESISTANCE & LIFE SAFETY:
BASEMENT UTILITIES & SEPARATION
1.
1.
FIRE-RESISTANCE RATING: A MINIMUM 1-HOUR FIRE-RESISTANCE RATING IS REQUIRED FOR
CONSULTANTS:
HEATING FACILITIES SEPARATION: FURNACES OR OTHER HEATING FACILITIES MUST BE "SO
THE WALLS, FLOORS AND CEILING ASSEMBLIES THAT SEPARATE TWO DWELLING UNITS.
LOCATED, INSULATED AND SEPARATED FROM THE LIVING AREA BY FIREPROOF PARTITIONS OR WALLS
2.
NECESSARY PURSUANT TO REGULATIONS OF THE FIRE CHIEF SO THAT THE SAME DOES NOT
CONSTRUCTION STANDARDS: THE ASSEMBLIES MUST BE TESTED IN ACCORDANCE WITH
STANDARDS SUCH AS ASTM E119 OR UL 263.
CONSTITUTE AN UNDUE HAZARD". THIS IMPLIES A REQUIREMENT FOR A PROTECTIVE BARRIER,
3.
TYPICALLY USING FIRE-RESISTANT MATERIALS LIKE DRYWALL, AROUND MAJOR UTILITY EQUIPMENT.
CONTINUITY: THE FIRE-RESISTANCE-RATED WALLS ASSEMBLIES MUST EXTEND FROM THE
FOUNDATION TO THE UNDERSIDE OF THE ROOF SHEATHING AND BE TIGHT AGAINST THE EXTERIOR
WALL.
4.
ATTIC EXCEPTION: THE WALL ASSEMBLY IS NOT REQUIRED TO EXTEND THROUGH THE ATTIC
THE EXACT RATING (E.G., 1-HOUR) SHOULD BE CONFIRMED WITH THE LOCAL TRENTON CITY FIRE
PLAN REVIEW INFO:
MARSHAL OR BUILDING OFFICIAL DURING THE PLAN REVIEW PROCESS.
2.
PROHIBITED STORAGE: THE CITY OF TRENTON'S CODE STRICTLY PROHIBITS THE STORAGE
SPACE IF THE CEILING IS PROTECTED BY AT LEAST 5/8-INCH TYPE X GYPSUM BOARD AND AN ATTIC OF HIGHLY FLAMMABLE OR COMBUSTIBLE LIQUIDS (MORE THAN FIVE GALLONS OF GASOLINE OR ONE
DRAFT STOP IS PROVIDED.
GALLON OF KEROSENE) WITHIN ANY PORTION OF A DWELLING UNIT, INCLUDING THE BASEMENT.
1 HR.
WP #
3240
5.
SPRINKLER
SYSTEM
EXCEPTION:
A
REDUCED 1/2-HOUR FIRE-RESISTANCE
RATING
IS
PERMITTED IF THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM.
STC
50-54
6.
CEILING MEMBRANE: TWO LAYERS OF 5/8-INCH-THICK, TYPE X GYPSUM WALLBOARD ON THE
UNDERSIDE OF THE FLOOR FRAMING ARE TYPICALLY REQUIRED.
7.
INSTALLATION: THE LAYERS MUST BE APPLIED AT RIGHT ANGLES TO THE JOISTS USING
SPECIFIC SCREW OR NAIL PATTERNS AND SPACING, WITH JOINTS OFFSET BETWEEN LAYERS. THE
JOINTS OF THE FACE LAYER MUST ALSO BE TAPED AND SPACKLED.
8.
CONTINUITY: THE FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY MUST EXTEND TO
AND BE TIGHT AGAINST THE EXTERIOR WALLS.
9.
ONE-HOUR
FIRE-RESISTANCE
RATING: REQUIRED
IF
THE
BUILDING
IS
JERSEY UNIFORM CONSTRUCTION CODE (NJUCC).
10.
ROUND NOSING ON STAIR
TREAD AS REQUIRED
3.
GENERAL STORAGE: BASEMENTS ARE PERMITTED FOR STORAGE AND LAUNDRY
USE,
PROVIDED THEY ARE DRY AND ADEQUATELY LIGHTED. THE UNIFORM FIRE CODE REQUIRES ALL
STORAGE OF COMBUSTIBLE MATERIALS TO BE ORDERLY AND NOT CONSTITUTE A HAZARD.
4.
PROJECT:
EGRESS: IF A BASEMENT IS USED AS AN ACTIVITY ROOM OR CONTAINS SLEEPING ROOMS, IT
MUST HAVE TWO INDEPENDENT MEANS OF EGRESS, ONE LEADING DIRECTLY TO THE OUTSIDE. THIS IS
A CRITICAL LIFE SAFETY REQUIREMENT RELATED TO FIRE SAFETY.
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
EQUIPPED
THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH THE NEW
ONE-HOUR FIRE-RESISTANCE RATING: REQUIRED IF THE BUILDING DOES NOT HAVE A
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
SPRINKLER SYSTEM INSTALLED. THIS SEPARATION MUST BE A WALL AND/OR FLOOR ASSEMBLY
10"
1"
2
TESTED IN ACCORDANCE WITH STANDARDS LIKE ASTM E119 AND MUST EXTEND FROM THE
FOUNDATION TO THE UNDERSIDE OF THE ROOF SHEATHING.
11.
WOOD TRIM BOARD
STAIRWAY WITHIN A SINGLE UNIT: FOR AN INTERIOR STAIRWAY THAT SERVES AND IS
71
2"
CONTAINED
11
2" THICK TREAD
BEARING
3" MIN.
PROPOSED OPENING WIDTH
BEARING
3" MIN.
ENTIRELY
WITHIN
A
SINGLE
RESIDENTIAL
DWELLING
UNIT,
NO
SPECIAL
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
ENCLOSED, USABLE SPACES UNDER SUCH STAIRWAYS ONLY NEED TO BE PROTECTED BY 1/2-INCH
12.
SHEET TITLE:
CORRIDOR FIRE-RESISTANCE RATING: CORRIDORS CONTAINED WITHIN A DWELLING UNIT OR
1"
24
A TWO-FAMILY DWELLING BUILDING ARE GENERALLY NOT REQUIRED TO HAVE A FIRE-RESISTANCE
PRE-CAST
CONCRETE LINTEL
RATING.
13.
DWELLING UNIT SEPARATION: WHILE THE CORRIDOR ITSELF MAY NOT REQUIRE A RATING,
THE WALL AND/OR FLOOR ASSEMBLIES THAT SEPARATE THE TWO DWELLING UNITS FROM EACH
02 LAYERS GYPSUM
FOR
FIRE-RESISTANCE-RATED ENCLOSURE IS MANDATED BY CODE. THE WALLS AND SOFFITS OF
GYPSUM BOARD.
3"
1
2" THICK RISER
DOOR / WINDOW
OTHER MUST HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN ONE HOUR. THIS SEPARATION IS
OPENING
REQUIRED REGARDLESS OF WHETHER A LOT LINE EXISTS BETWEEN THE UNITS.
BOARD AS SPECIFIED
DETAIL:
TYPICAL TREAD / RISER
16.
ROOMS, BATH ROOMS AND KITCHEN ENTRANCES AND 60” FOR KITCHENS WORKING SPACES AND
NOT LESS THAN 7 FEET.
W/O SHEAR WALL SHEATHING
3
4"
HARDWARE, GLAZING, ETC.) MUST BE LISTED AND LABELED FOR THEIR INTENDED USE.
ATTICS/LOFTS.
DIRECTLY TO THE OUTDOORS.
5/8" TYPICAL x GYPSUM BOARD ON
RESILIENT CHANNELS SYSTEM 24" O.C.
ON UNIT SIDE 2x4 OR 2x6 WOOD STUDS
@ 16" MAXIMUM O.C. W/ SHEATHING PER
STRUCTURE 5/8" TYPICAL x GYPSUM
BOARD AND FIBER CEMENT SIDING AT
CORRIDOR.
COMPONENTS: ALL COMPONENTS OF THE FIRE DOOR ASSEMBLY (DOOR, FRAME, HINGES,
INCLUDING ADEQUATE MANEUVERING SPACE OF NOT LESS THAN 42” IN ALL CASES AT DOORS OF BED
5.
W/ SHEAR WALL SHEATHING
CORRIDOR / TENANT SEPARATION WALL
AT WET LOCATIONS
15.
1.
ACCESSIBILITY REQUIREMENTS: EACH TWO-DWELLING UNIT STRUCTURE HAVE 39 INCH
DESCRIPTION
IN NFPA 80. THIS STANDARD COVERS REQUIREMENTS FOR COMPONENTS LIKE THE DOOR, FRAME,
HINGES, AND ALL HARDWARE.
THE FEDERAL FAIR HOUSING ACT (FHA) AND THE NEW JERSEY UNIFORM CONSTRUCTION CODE (NJAC),
INTERIOR DOORS: EACH DWELLING UNITS THAT ARE NOT REQUIRED TO BE ACCESSIBLE
DATE
NFPA 80 COMPLIANCE: THE LABELING AND INSTALLATION MUST COMPLY WITH THE STANDARDS SET
SMOKE ALARM REQUIREMENTS:
PRIMARY EGRESS DOOR (EXTERIOR): EACH DWELLING UNIT HAVE ONE SIDE-HINGED EGRESS
NO.
REQUIREMENTS. THE LABELS MUST BE PERMANENTLY AFFIXED AND CLEARLY VISIBLE AND LEGIBLE.
ACCESSIBLE INTERIOR ROUTE THROUGHOUT TO MEET THE DICTATED MINIMUM REQUIREMENTS BY
B USER PASSAGE DOORS), MANEUVERING SPACE, AND HARDWARE.
1 HR.
UL #356
CORRIDOR / TENANT SEPARATION WALL
05
APPROVED AGENCY (SUCH AS UL) TO DEMONSTRATE THEY HAVE MET SPECIFIC FIRE TEST
REVISIONS
REQUIREMENTS FOR CLEAR WIDTH (MINIMUM 32 INCHES CLEAR OPENING, OR 31.75 INCHES FOR TYPE
STC 53
5/8" TYPICAL x GYPSUM BOARD ON
RESILIENT CHANNELS SYSTEM 24" O.C.
ON UNIT SIDE 2x4 OR 2x6 WOOD STUDS
@ 16" MAXIMUM O.C. W/ SHEATHING PER
STRUCTURE 5/8" TYPICAL x GYPSUM
BOARD AND FIBER CEMENT SIDING AT
CORRIDOR.
LABELED ASSEMBLIES: FIRE DOOR ASSEMBLIES ARE REQUIRED TO BE LABELED BY AN
DETAIL :
PROPOSED OPENINGS PRECAST LINTEL
ARCHITECTURAL
DETAILS
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
CHECKED:
SJ & AG
A-4
DWG. NO.
04 OF 13
REVISIONS
FLOOD NOTE:
NO.
DATE
DESCRIPTION
BY GRAPHIC PLOTTING ONLY, THIS PROPERTY IS LOCATED
ZONE 'X' (AREAS DETERMINED TO BE OUTSIDE THE 0.20%
ANNUAL CHANCE FLOODPLAIN) OF THE FLOOD INSURANCE
RATE MAP, MAP NO. 34021C0209F. WHICH BEARS AN
EFFECTIVE DATE OF JULY 20, 2016.
AN ELEVATION CERTIFICATE MAY BE NEEDED TO VERIFY
THIS DETERMINATION TO APPLY FOR A VARIANCE. BEFORE
THE
PREPARATION
OF
DESIGN
PLANS
PLEASE
VISIT
FEMA.GOV TO CONFIRM THE INFORMATION LISTED ABOVE.
ARCHITECT:
NOTES:
1.
PROPERTY KNOWN AS LOT 3, BLOCK 10304 AS
IDENTIFIED ON THE OFFICIAL TAX MAPS OF THE CITY OF
TRENTON, MERCER COUNTY, STATE OF NEW JERSEY.
.01
35
BY A SURVEY PREPARED IN THE FIELD BY BLUE MARSH
ASSOCIATES, INC. AND OTHER REFERENCE MATERIAL AS
LISTED HEREON. THIS SURVEY WAS PREPARED WITHOUT
THE BENEFIT OF A TITLE COMMITMENT REPORT.
5.
THE EXISTENCE OF
FIELD SURVEY.
PROPERTY
SUBJECT
TO
RESTRICTIONS,
SYSTEM DATA COLLECTION.
ENCROACHMENTS AND VAULTS, IF ANY, BELOW
STRUCTURE,
FENCE,
10.
CORNER MARKER WAIVER OBTAINED FROM THE
ULTIMATE
USER AS PROVIDED BY
THE REGULATION
(N.J.A.C. 13:40-5.2) OF THE BOARD OF PROFESSIONAL
ENGINEERS AND LAND SURVEYORS.
8.00'
3
6.7
5
6.6
3
3
.57
34
5
.7
34
3.70'
6' HIGH
CHAIN LINK
FENCE
18.47'
.35
.41
37
.36
37
GATE
7
7.1
.17
37
.56
37
9
7.3
GATE 3
CONC. AREA
.71
36
.83
36
PAVER
AREA
.09
37
36
-.
-.
.59
36 .76
TW 35
BW
.74
36 .63
TW 35
3
4
BW
.
35
.39
35
14
35.
CONC. WALK
9
5.7
3
.69
35 .73
TW 35
BW
.35
36 .97
TW 35
BW
.68
35
.42
35
54
34.
49
34. 38
C
99
T 34.
34. 57
G
C
T 34.
G
GV
6
5.0 3
3
6
TC 34.
G
7
5.0 9
3
6
TC 34.
G
CURB
CHANGE
TION
APPROX. LOCA
OF UG GAS LINE
ARKOUT)
(PER UTILITY M
(SEE NOTE 3)
1
5.6 2
3
3
TC 35.
G
.49
36 .39
TW 36
BW
.31 6.39
3
.93
35
GRANITE CURB
COUNTY'S SURVEY PLAT
NEW JERSEY.
SCALE 1/8" = 1'
8
5.9 8
3
TC 35.6
G
T
L STREEAY
FEDERA)(P
)
UBLIC ROADW
PROJECT:
CONC. WALK
36
.95
35
.46
37
8
-
7
6.4
3
7
.5
36 .40
W
6
T
3
BW
.W
(60' WIDE R.O
ADWAY)
H
(ASP ALT RO
FIC
TWO WAY TRAF
OF THE CITY OF TRENTON, MERCER COUNTY, STATE OF
36
.66
36
CONC. WALL
.65
35
PAVER AREA
37
34.
TC 34.33
G
.59
37
PLAN REVIEW INFO:
.48
37
.76
36
.74
CELLAR
DOORS
ELEC.
METER
P.O.B.
(OVERALL &
TRACT I)
34
25
34. 11
C
T
4.
G-
C
T 34.
G
.82
37
TRACT I
.63
36
34.
CONSULTANTS:
3
.31
STOP
SIGN
TAX MAP SHEET #103 OF THE OFFICIAL TAX MAPS
RAISED
DECK
.32
37
37
REFERENCES:
1.
1
.7
36
CONC. AREA
DEP. CURB
PERMANENT ADDITION ETC.
.64
37
THREE STORY
FRAME BUILDING
3
100.50'
.73
K
ANY
BLOCK 10304
LOT 2
14.60'
6
7.7
53.50'
34
AL
OF
.58
34
AREA LIGHT
INLET
TC = 34.65
GRT = 33.96
INV = 31.96
ER)
(FILLED W/ WAT
.04
38
GV
.W
THE OFFSETS SHOWN ARE NOT TO BE USED FOR
CONSTRUCTION
WV
NC
THE
CO
CO
SURFACE NOT SHOWN HEREON.
9.
TWO STORY
MASONRY BUILDING
(#346 CENTRE STREET)
BLDG. HT. = 28.00 FEET (±)
DEED LINE
(PER D.B. 4154,
PG. 21)
8
4.5 7
3
0
TC 34.
G
ELEVATIONS ARE BASED UPON (NAVD 88) DATUM
ESTABLISHED ONSITE UTILIZING GLOBAL POSITIONING
8.
34
3
2
.9
37
.31
36
47.00'
ION
APPROX. LOCAT
NE
OF UG ELEC. LI
ARKOUT)
(PER UTILITY M
(SEE NOTE 3)
COVENANTS AND/OR EASEMENTS, WRITTEN OR IMPLIED.
7.
.84
3.87'
19.56'
THIS
UP/LP #63790TH
W/ CONDUIT
1
4.7
TRACT II
LANDS N/F
YOUNG JOON AND UN YON
D.B. 4154, PG. 21
UNDERGROUND STORAGE
TANKS, IF ANY, WAS NOT KNOWN AT THE TIME OF THE
6.
3
4
4.7 0
3
TC 34.3
G
.03
38
62.55'
S 07° 00' 00" E
THIS PLAN IS BASED ON INFORMATION PROVIDED
1
4.9
BLOCK 10304
LOT 3
28.08'
4.
-'
1.00'
PROPER UTILITY COMPANY.
5.70'
GV
CONC. WALK
VERIFIED AS TO THEIR LOCATION, SIZE AND TYPE BY THE
CENTRE STREET
PREPARATION OF DESIGN PLANS AND/OR EXCAVATION IS
(66' WIDE R.O.W)(PUBLIC ROADWAY)
(ASPHALT ROADWAY)
TWO WAY TRAFFIC
UNDERGROUND UTILITIES AND STRUCTURES. BEFORE THE
.37
38
5
.1
38
CONC.
AREA
SIGN
5
4.8 4
3
TC 34.3
G
UTILITY MARK-OUT DOES NOT ENSURE MAPPING OF ALL
TO BEGIN, ALL UNDERGROUND UTILITIES SHOULD BE
68.00'
38.72'
TIME OF THE SURVEY. AVAILABLE AS BUILT PLANS AND
ARCHITECTURE
INTERIOR DESIGN
.60
38
.23
38
15.00'
MAPS AS LISTED IN THE REFERENCES AVAILABLE AT THE
32.50'
40.92'
WERE VISIBLE AND ACCESSIBLE IN THE FIELD AND THE
.50
-.
15.72'
TION
APPROX. LOCA
OF UG GAS LINE
ARKOUT)
(PER UTILITY M
(SEE NOTE 3)
UTILITY MARK OUTS ABOVE GROUND STRUCTURES THAT
.87
34
DEP. CURB
APPROXIMATE. ALL LOCATIONS AND SIZES ARE BASED ON
.55
35
.58
35
2.10'
1
4.5 3
3
TC 34.4
G
39.82'
LOCATION OF ALL UNDERGROUND UTILITIES ARE
CONC. CURB
3.
38
AUGUSTUS GEHRY
ARCHITECT
.21
39
.16
39
S 07° 00' 00" E
OVERALL AREA = 7,825 SF OR 0.180 AC.
119.00'
N 81° 50' 57" E(S)
N 81° 50' 55" E(D)
.68
35
5.22'
.63
35
P.O.B.
(TRACT II)
GATE
TRACT-II AREA = 5,010 SF OR 0.115 AC.
WV
1.10'
9
4.5 8
3
TC 34.4
G
TRACT-I AREA = 2,815 SF OR 0.065 AC.
69.00'
N 07° 00' 00" W
2.
.87
36
6
6.2
3
7
6.2 8
3
TC 35.9
G
DEP. CURB
2
6.5 8
3
TC 36.2
G
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
FOR
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
SHEET TITLE:
2.
MAP ENTITLED "FIRM FLOOD INSURANCE RATE
MAP, MERCER
COUNTY, STATE
(ALL JURISDICTIONS)",
PREPARED BY FEDERAL EMERGENCY AGENCY, PANEL 209
OF 276, MAP NUMBER 34021C0209F, DATE: JULY 20,
2016.ES.
COUNTY'S
SURVEY PLAT
AND
EXISTING BUILDING
LAYOUT
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
CHECKED:
SJ & AG
A-5
DWG. NO.
05 OF 13
REVISIONS
NO.
DATE
DESCRIPTION
100'-6"
32'-6"
EW5
EW5
EW5
EW5
EW5
ARCHITECT:
8'-1"
2'-11
4"
68'
ED2
9'-7"
40'-6"
52'
77'-11
2"
3'-9"
EDT
AUGUSTUS GEHRY
ARCHITECT
83'
EW1
86'-9"
ARCHITECTURE
INTERIOR DESIGN
ED2
-
DN
EST-06
CEILING HEIGHT = 12'-2" AND DECK THICKNESS = 12"
33'-11"
6'
16'-6"
38'-85
8"
32'-6"
ED1
25'-10"
39'-10"
48'-6"
14'-11"
EST-07
UP
64'-6"
16'
26'-2"
ED2
92'-9"
EW3
86'-9"
EW1
OVERHEAD
M.S BALCONY
CONSULTANTS:
83'-3"
78'
56'-87
8"
16'-3"
UP
EST-06
PLAN REVIEW INFO:
ED3
3'-3"
ED2
15'-85
8"
7'-8"
67'-6"
1'
ED2
EW5
47'
EW5
EW5
EW5
EW5
6'-6"
53'-6"
PROJECT:
EXISTING FIRST FLOOR PLAN
EXISTING OPENINGS SCHEDULE
SCALE 1/4" = 1'
NAME
DESCRIPTION
FRAME
WIDTH
FRAME
HEIGHT
CLEAR
WIDTH
CLEAR
HEIGHT
SILL
HEIGHT
HUNG TYPE
ED1
DOOR DOUBLE
72"
78"
69"
76.5"
00"
SIDES HUNG
ED2
DOOR SINGLE
36"
78"
33"
76.5"
32"
SIDE HUNG
ED3
DOOR SINGLE
32"
78"
29"
76.5"
32"
SIDE HUNG
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
FOR
EDT
TRAP DOOR
32"
78"
29"
76.5"
32"
SIDE HUNG
EW1
WINDOW
65"
46"
62"
43"
34"
UPWARD SLIDE
EW2
WINDOW
70"
46"
67"
43"
32"
UPWARD SLIDE
EW3
WINDOW
43"
46"
40"
43"
32"
UPWARD SLIDE
EW4
WINDOW
34"
46"
31"
43"
32"
UPWARD SLIDE
EW5
WINDOW
32"
46"
29"
43"
32"
UPWARD SLIDE
EW6
WINDOW
30"
46"
27"
43"
32"
UPWARD SLIDE
EW7
WINDOW
20"
24"
17"
21"
54"
TOP HUNG
EW8
WINDOW
22"
46"
19"
43"
32"
UPWARD SLIDE
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
SHEET TITLE:
EXISTING
FIRST FLOOR
ARCHITECTURAL
PLAN
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
CHECKED:
SJ & AG
A-6
DWG. NO.
06 OF 13
REVISIONS
NO.
DATE
DESCRIPTION
100'-6"
32'-6"
68'
EW6
EW6
EW6
EW6
EW6
EW6
EW7
EW6
EW6
ARCHITECT:
5'-3"
EW8
EW4
ED2
EW4
AUGUSTUS GEHRY
ARCHITECT
EW4
ARCHITECTURE
INTERIOR DESIGN
EW2
38'-85
8"
39'-10"
CEILING HEIGHT = 9'-5", DECK THICKNESS = 8" AND FROM TOP OF DECK TO ROOF PEAK HEIGHT = 4'-3"
EW2
OVERHEAD ROOF
PROJECTION
EW6
CONSULTANTS:
EW7
EW7
ED3
16'-3"
UP
EST-06
PLAN REVIEW INFO:
3'-3"
ED2
EW6
EW6
EW6
47'
EW6
EW6
53'-6"
6'-6"
6"
PROJECT:
EXISTING SECOND FLOOR PLAN
EXISTING OPENINGS SCHEDULE
SCALE 1/4" = 1'
NAME
DESCRIPTION
FRAME
WIDTH
FRAME
HEIGHT
CLEAR
WIDTH
CLEAR
HEIGHT
SILL
HEIGHT
HUNG TYPE
ED1
DOOR DOUBLE
72"
78"
69"
76.5"
00"
SIDES HUNG
ED2
DOOR SINGLE
36"
78"
33"
76.5"
32"
SIDE HUNG
ED3
DOOR SINGLE
32"
78"
29"
76.5"
32"
SIDE HUNG
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
FOR
EDT
TRAP DOOR
32"
78"
29"
76.5"
32"
SIDE HUNG
EW1
WINDOW
65"
46"
62"
43"
34"
UPWARD SLIDE
EW2
WINDOW
70"
46"
67"
43"
32"
UPWARD SLIDE
EW3
WINDOW
43"
46"
40"
43"
32"
UPWARD SLIDE
EW4
WINDOW
34"
46"
31"
43"
32"
UPWARD SLIDE
EW5
WINDOW
32"
46"
29"
43"
32"
UPWARD SLIDE
EW6
WINDOW
30"
46"
27"
43"
32"
UPWARD SLIDE
EW7
WINDOW
20"
24"
17"
21"
54"
TOP HUNG
EW8
WINDOW
22"
46"
19"
43"
32"
UPWARD SLIDE
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
SHEET TITLE:
EXISTING
SECOND FLOOR
ARCHITECTURAL
PLAN
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
CHECKED:
SJ & AG
A-7
DWG. NO.
07 OF 13
REVISIONS
NO.
DATE
DESCRIPTION
100'-6"
32'-6"
2'-11
4"
68'
3'-3"
15'-8"
DN
8'-1"
3'-3"
EST-01
EST-03
8'-10"
UP
ARCHITECT:
15'-8"
3'-9"
AUGUSTUS GEHRY
ARCHITECT
ARCHITECTURE
INTERIOR DESIGN
ED2
-
UP
14'-11"
CEILING HEIGHT = 8'-1" AND DECK THICKNESS = 10"
48'-6"
38'-85
8"
39'-10"
32'-6"
16'-6"
64'-6"
16'
15'-85
8"
CONSULTANTS:
14'-10"
14'-5"
PLAN REVIEW INFO:
3'-3"
EST-04
DN
1'
DN
3'-3"
EST-02
47'
53'-6"
PROJECT:
EXISTING BASEMENT FLOOR PLAN
EXISTING OPENINGS SCHEDULE
SCALE 1/4" = 1'
NAME
DESCRIPTION
FRAME
WIDTH
FRAME
HEIGHT
CLEAR
WIDTH
CLEAR
HEIGHT
SILL
HEIGHT
HUNG TYPE
ED1
DOOR DOUBLE
72"
78"
69"
76.5"
00"
SIDES HUNG
ED2
DOOR SINGLE
36"
78"
33"
76.5"
32"
SIDE HUNG
ED3
DOOR SINGLE
32"
78"
29"
76.5"
32"
SIDE HUNG
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
FOR
EDT
TRAP DOOR
32"
78"
29"
76.5"
32"
SIDE HUNG
EW1
WINDOW
65"
46"
62"
43"
34"
UPWARD SLIDE
EW2
WINDOW
70"
46"
67"
43"
32"
UPWARD SLIDE
EW3
WINDOW
43"
46"
40"
43"
32"
UPWARD SLIDE
EW4
WINDOW
34"
46"
31"
43"
32"
UPWARD SLIDE
EW5
WINDOW
32"
46"
29"
43"
32"
UPWARD SLIDE
EW6
WINDOW
30"
46"
27"
43"
32"
UPWARD SLIDE
EW7
WINDOW
20"
24"
17"
21"
54"
TOP HUNG
EW8
WINDOW
22"
46"
19"
43"
32"
UPWARD SLIDE
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
SHEET TITLE:
EXISTING
BASEMENT FLOOR
ARCHITECTURAL
PLAN
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
CHECKED:
SJ & AG
A-8
DWG. NO.
08 OF 13
REVISIONS
NO.
100'-6"
4'-6"
32'-6"
10'
2'-1"
4'
4'
51
2"
21
2"
8'-6"
3'-1"
6'-8"
12'-67
8"
1'
7"
EXIT/ACCESS PST-05
-
FFL: 1'-0"
D-
18'-5"
BED ROOM
EW5
ELECTRIC
PANEL
UNIT D = 806 SQ FT
FFL: 1'-0"
LIVING
KITCHEN
2'-6"
4'-7"
8'
3'-6"
01
D6
MECH.
EW5
47'
D2
DN
EW5
9'-4"
EXIT/ACCESS EST-04
14
02
13
EW5
-
12
PLAN REVIEW INFO:
EW5
6'-2"
53'-6"
PROPOSED FIRST FLOOR PLAN
CONSULTANTS:
17'-5"
7'
03
W4
DN
38'-85
8"
3'-6"
CLEAR WIDTH
2'
10'-10"
DINING
BATH
ROOM
3'
4'-91
2"
FFL:2'-8"
4'-6"
EW3
2'-107
8"
3'-21
2"
3'-3"
3'-7"
6'
12'-87
8"
4"
11'
8'
D2
6'
2'-6"
-
8'-6"
BED ROOM
6'-6"
D2
5'-1"
2'-57
8"
7'-1"
3'-3"
D3
4"
4"
BED ROOM
2'-67
8"
13'-47
8"
13'-47
8"
3'
13'-9"
11'-9"
DN 3'-6"
02
13'-07
8"
4'
61
2"
5'-1"
6'-8"
D4
D3
4"
91
2"
2'-9"
10"
ELECTRIC
PANEL
9'-81
2"
1'-1"
ARCHITECTURE
INTERIOR DESIGN
10'-97
8"
D8
HALLWAY
7"
3'-3"
10"
EW2
3'-3"
4'-5"
D8
HALLWAY
8'-6"
AUGUSTUS GEHRY
ARCHITECT
4'-6"
4'-11"
3'-3"
7'-2"
3'-10"
CLOSET
D3
2'-9"
7"
CLOSET
01
UP
LIVING
FFL:0'-0"
D4
3'-3"
04
03
11'
3'-6"
3'-6"
CLOSET
D3
CLEAR WIDTH
CLOSET
3'-3"
4'
9'-3"
EXIT/ACCESS EST-02
4'-11"
D4
05
02
FFL: 1'-0"
COUNTER
3'-6"
2'-9"
5'-5"
14
17'-81
2"
D3
ARCHITECT:
06
DINING
14'-87
8"
2'-5"
D8
07
13
EXIT/ACCESS EST-03
DN
D2
7'
CLEAR WIDTH
7"
D7
-
UNIT C = 824 SQ FT
14'-47
8"
HALLWAY
91
2"
4'
2'-6"
3'-6"
D2
HALLWAY
51
2"
5'
COUNTER
D2 01
6'-10"
3'-3"
5'-9"
3'-6"
10"
7'-107
8"
13'-5"
19'-11"
BEDROOM
01
4" 2'-61
2" 4"
KITCHEN
14'-47
8"
3'-3"
7'
KITCHEN
-
EW5
MECH.
D6
BATH
ROOM
4'-6"
2'-9"
D3
BATH
ROOM
DINING
8'-6"
4"
4"
4"
D3
CLEAR WIDTH
3'-6"
CLEAR WIDTH
3'-6"
CLEAR WIDTH
2'
D4
FFL: 1'-0"
LIVING
9'-5"
EW1
2'-6"
21
2"
61
2"
7'
6"
6"
UNIT B = 898 SQ FT
EW5
5'-1"
4'
2'
6'-7"
3'-6"
3'-6"
D2
BED ROOM
BED ROOM
7'
3'
3'
BED ROOM
12'-87
8"
9'
BATH
ROOM
FFL: 1'-0"
ELECTRIC
PANEL 20'
EW5
11'-07
8"
8'-6"
5'-2"
DINING
ELECTRIC
PANEL
39'-97
8"
D2
W1
1'-107
8" 2'-6"
8'-11"
4"
KITCHEN
UNIT A = 901 SQ FT
15'-81
2"
EW5
08
7'-2"
14'-10"
COUNTER
EW5
8'-4"
15'-2"
3'-21
2"
LIVING
14'-10"
10'-10"
10"
6"
3'-6"
W1
02
01
17'-81
2"
EW1
4'-51
2"
9'
11'
DN
D2
MECH.
D6
2'-6"
3'-6"
EXIT/ACCESS EST-01
14
3'-6"
EXIT/ACCESS PST-07
3'-6"
W4
02
DESCRIPTION
68'
-
13
DATE
PROPOSED OPENINGS SCHEDULE
SCALE 1/4" = 1'
PROJECT:
NAME
DESCRIPTION
FRAME
WIDTH
FRAME
HEIGHT
CLEAR
WIDTH
CLEAR
HEIGHT
SILL
HEIGHT
HUNG TYPE
D1
DOOR DOUBLE
54"
78"
51"
76.5"
20"
SIDES HUNG
D2
DOOR SINGLE
42"
78"
39"
76.5"
00"
SIDE HUNG
D3
DOOR SINGLE
39"
78"
36"
76.5"
00"
SIDE HUNG
D4
DOOR SINGLE
33"
78"
30"
76.5"
00"
SIDE HUNG
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
D5
DOOR SINGLE
30"
78"
27"
76.5"
00"
SIDE HUNG
FOR
D6
DOOR DOUBLE
30"
78"
27"
75.5"
00"
SIDES HUNG
D7
DOOR DOUBLE FOLDING
60"
72"
57"
70.5"
00"
SIDE HUNG
D8
DOOR DOUBLE FOLDING
48"
72"
45"
70.5"
00"
SIDE HUNG
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
SHEET TITLE:
D9
DOOR DOUBLE FOLDING
42"
72"
39"
70.5"
00"
SIDE HUNG
W1
WINDOW
48"
46"
45"
43"
32"
UPWARD SLIDE
W2
WINDOW
42"
46"
39"
43"
32"
UPWARD SLIDE
W3
WINDOW
39"
46"
36"
43"
32"
UPWARD SLIDE
W4
WINDOW
25"
46"
22"
43"
32"
UPWARD SLIDE
W5
WINDOW
25"
46"
22"
43"
34"
UPWARD SLIDE
PROPOSED
FIRST FLOOR
ARCHITECTURAL
PLAN
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
CHECKED:
SJ & AG
A-9
DWG. NO.
09 OF 13
REVISIONS
NO.
4'-6"
100'-6"
32'-6"
3'-6"
W5
21
2"
W3
EW6
4'
11"
DN
EXIT/ACCESS PST-06
D2
MECH.
FFL: 14'-2"
1'-10"
4'-41
2"
D3
2'-9"
2'-8"
-
3'-6"
4'
12'-97
8"
11'-2"
7'
5'-1"
BED ROOM
BED ROOM
16'-67
8"
6'-8"
2'-6"
41
2"
81
2"
38'-85
8"
14'-77
8"
CONSULTANTS:
KITCHEN
ELECTRIC
PANEL
DINING
3'-11"
3'-11"
8'
D6
MECH.
8'
8'
EW6
W1
EW6
EW6
D2
PLAN REVIEW INFO:
EW6
6'-2"
NAME
DESCRIPTION
FRAME
WIDTH
FRAME
HEIGHT
CLEAR
WIDTH
CLEAR
HEIGHT
SILL
HEIGHT
HUNG TYPE
D1
DOOR DOUBLE
54"
78"
51"
76.5"
20"
SIDES HUNG
D2
DOOR SINGLE
42"
78"
39"
76.5"
00"
SIDE HUNG
D3
DOOR SINGLE
39"
78"
36"
76.5"
00"
SIDE HUNG
D4
DOOR SINGLE
33"
78"
30"
76.5"
00"
SIDE HUNG
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
D5
DOOR SINGLE
30"
78"
27"
76.5"
00"
SIDE HUNG
FOR
D6
DOOR DOUBLE
30"
78"
27"
75.5"
00"
SIDES HUNG
D7
DOOR DOUBLE FOLDING
60"
72"
57"
70.5"
00"
SIDE HUNG
D8
DOOR DOUBLE FOLDING
48"
72"
45"
70.5"
00"
SIDE HUNG
PST-06
-
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
SHEET TITLE:
2'
COUNTER
10" 2'-6" 10"
D2
11"
6"
PROJECT:
D9
DOOR DOUBLE FOLDING
42"
72"
39"
70.5"
00"
SIDE HUNG
W1
WINDOW
48"
46"
45"
43"
32"
UPWARD SLIDE
W2
WINDOW
42"
46"
39"
43"
32"
UPWARD SLIDE
W3
WINDOW
39"
46"
36"
43"
32"
UPWARD SLIDE
W4
WINDOW
25"
46"
22"
43"
32"
UPWARD SLIDE
3'-6"
DN
FFL: 14'-2"
21
D2
7'
CLEAR WIDTH
3'-6"
CLEAR WIDTH
19'-10"
FFL: 1'-0"
13'-07
8"
FFL: 14'-2"
18'-2"
D6
MECH.
3'-10"
ELECTRIC
PANEL
11'-3"
UP
EW2
15'-1"
2'-2"
7'
D3
15'-10"
LIVING
DINING
3'-6"
2'-9"
BATH ROOM
4'-6"
10"
ELECTRIC
PANEL
D4
3'-3"
13'-45
8"
4'
3'-3"
D3
FFL: 14'-2"
EW6
D2
D4
3'-3"
10'-1"
13'-77
8"
3'-6"
D3
UNIT F = 742 SQ FT
LIVING
12'
BATH
ROOM
3'-7"
FFL: 14'-2"
6'-7"
11"
CLOSET
D9
15'-27
8"
3'-3"
HALLWAY
3'-3"
6'-77
8"
9'-9"
3'-6"
3'-3"
9'-67
8"
39'-10"
3'-3"
UNIT E = 979 SQ FT
ARCHITECTURE
INTERIOR DESIGN
PROPOSED OPENINGS SCHEDULE
4'-6"
EW6
3'-3"
UNIT H = 854 SQ FT
SCALE 1/4" = 1'
BEDROOM
7"
BATH
ROOM
PROPOSED SECOND FLOOR PLAN
D3
EW2
15'-10"
53'-6"
DINING
AUGUSTUS GEHRY
ARCHITECT
LIVING
47'
D3
5'-1"
3'
5'-11
2"
ELECTRIC
PANEL
LIVING
7"
3'-3"
5'-1"
4"
W4
BEDROOM
13'-17
8"
D4
10'-11"
2'
9'-4"
-
09
12'-87
8"
D3
9'-6"
KITCHEN
01
02
81
2"
3'-6"
CLEAR WIDTH
8'
D6
D6
04
3'-11"
2'-6"
41
2"
3'-9"
2'-9"
10" 2'-6" 10"
D2
3'
MECH.
3'-3"
1'-3"
2'-67
8"
11'-3"
7'
4"
2'-6"
3'-3"
6'-11"HALLWAY 3'-3"
BED ROOM
3'-6"
3'-6"
2'-6"
4"
ELECTRIC
PANEL
COUNTER
6'-11"
D3
HALLWAY
7'
ELECTRIC
PANEL
2'-2"
2'-9"
D4
10"
05
DINING
18'-27
8"
12'-97
8"
9'-8"
3'-6"
BATH ROOM
3"
15'-1"
CLEAR WIDTH
EW6
10"
81
2"
3'-10"
12'
13'-77
8"
6'-7"
LIVING
4'
16'-8"
2'-9"
3"
D8
DINING
3'-3"
D3
3'-6"
CLOSET
D4
CLEAR WIDTH
UNIT F = 742 SQ FT
5'-5"
LIVING
D3
3'-6"
5'-5"
D2
ARCHITECT:
FFL: 14'-2"
CLEAR WIDTH
CLOSET
06
KITCHEN
UNIT G = 815 SQ FT
14'-87
8"
FFL: 14'-2"
D9
3'-3"
BATH
ROOM
07
03
12'-117
8"
1'-117
8" 2'-6"
3'
2'-8"
10"
3'-7"
BEDROOM
14'-47
8"
2'-9"
D3
D6
MECH.
3'-11"
BEDROOM
7" 4"
2'-10
2'-6"
8
9'-9"
EW6
EW6
-
14'-47
8"
3'-3"
9"
3'-6"
BEDROOM
9'-10"
DN
EW6
8'
4"
4'-6"
D4
3'-6"
4'
CLOSET
D9
21
2"
4'-6"
3'-6"
10'-1"
UNIT E = 979 SQ FT
11"
BATH
ROOM
D3
8'
4"
12'
12'
1'-8"
3'
BED ROOM
FFL: 14'-2"
3'
EW6
5'-1"
13'-45
8"
3'-3"
HALLWAY
D3
3'-3"
3'-3"
6'-77
8"
DINING
39'-10"
8'
4"
12'
9'-9"
11'-9"
4'-6"
D3
2'-6"
EW6
8'
5'-1"
BEDROOM
4"
W2
EW6
8'
BEDROOM
4"
D3
BEDROOM
2'
3'-3"
3"
8'
8'
COUNTER
3'-3"
EW4
9'-67
8"
EW6
2'-6"
7'-3"
KITCHEN
3'-6"
10"
EW4
EW6
EW6
EXIT/ACCESS PST-07
8'-4"
4'-9"
D8 CLOSET
D3
9'-10"
3'-6"
08
4'
BEDROOM
DESCRIPTION
68'
91
2"
8'-6"
EW4
10'
DATE
KITCHEN
2'-101
2
10'-10"
3'-4"
W5
WINDOW
25"
46"
22"
43"
34"
UPWARD SLIDE
PROPOSED
SECOND FLOOR
ARCHITECTURAL
PLAN
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
47'
CHECKED:
SJ & AG
A-10
DWG. NO.
10 OF 13
REVISIONS
NO.
DATE
DESCRIPTION
100'-6"
32'-6"
-
1'-7"
7"
10'-10"
UP-
12'-67
8"
03 02 01
3'
4'
FFL: -(7'-11")
91
4"
10'-97
8"
ELECTRIC
PANEL
CONSULTANTS:
17'-6"
4'-101
2"
-
14
15'-41
2"
02
13
03
47'
UP
D2
-
12
3'-3"
5'
CLOSET
21'-71
2"
01
3'-7"
3'-101
4"
5'-07
8"
CLOSET
5'-5"
3'-6"
02
PART OF UNIT D = 426 SQ FT
51
4"
4'-87
8"
UP
D1
D8
01
5'-9"
9'-3"
EXIT/ACCESS EST-02
FFL: 1'-0"
28'-61
2"
6"
4'
D7
6'-10"
FFL: 2'-8"
4'-6"
STORAGE ROOM
6"
10"
6'-6"
D3
5'-10"
PART OF UNIT B = 455 SQ FT
9'-81
2"
38'-85
8"
35'-85
8"
FFL: -(7'-11")
5'-10"
11'-3"
STORAGE ROOM
ARCHITECTURE
INTERIOR DESIGN
1'
D3
D3
D2
3'-3"
28'-61
2"
FFL: -(7'-11")
AUGUSTUS GEHRY
ARCHITECT
STORAGE ROOM
6"
34'-85
8"
3'
FFL: -(7'-11")
UTILITIES/MECHANICAL SPACE 1615 SQ FT
6"
5'-117
8"
29'-2"
3'-6"
39'-97
8"
SPACE ALLOCATED FOR SERVICES AND THEIR MAINTENANCE
FFL: -(7'-11")
PART OF UNIT C = 499 SQ FT
ELECTRIC
PANEL
38'-85
8"
D3
29'-6"
91
4"
7'-107
8"
3'
51
4"
6"
29'-2"
4'
4'-6"
5'-10"
11'-3"
STORAGE ROOM
FFL: -(7'-11")
UP
D8
51
4"
FFL: -(7'-11")
ELECTRIC
PANEL
D2
5'
3'-6"
PART OF UNIT A = 455 SQ FT
14
01
3'
ELECTRIC
PANEL
CLOSET
ARCHITECT:
13
02
3'-7"
39'-11
2"
D7
91
4"
8'-6"
4'-101
2"
5'-5"
01
5'-5"
D2
-
CLOSET
CLEAR WIDTH
5'-9"
14
UP
5'-101
2"
5'-9"
8'-11
2"
3'-10"
02
3'-6"
13
68'
6'-6"
53'-6"
PROPOSED BASEMENT FLOOR PLAN
PLAN REVIEW INFO:
PROPOSED OPENINGS SCHEDULE
SCALE 1/4" = 1'
PROJECT:
NAME
DESCRIPTION
FRAME
WIDTH
FRAME
HEIGHT
CLEAR
WIDTH
CLEAR
HEIGHT
SILL
HEIGHT
HUNG TYPE
D1
DOOR DOUBLE
54"
78"
51"
76.5"
20"
SIDES HUNG
D2
DOOR SINGLE
42"
78"
39"
76.5"
00"
SIDE HUNG
D3
DOOR SINGLE
39"
78"
36"
76.5"
00"
SIDE HUNG
D4
DOOR SINGLE
33"
78"
30"
76.5"
00"
SIDE HUNG
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
D5
DOOR SINGLE
30"
78"
27"
76.5"
00"
SIDE HUNG
FOR
D6
DOOR DOUBLE
30"
78"
27"
75.5"
00"
SIDES HUNG
D7
DOOR DOUBLE FOLDING
60"
72"
57"
70.5"
00"
SIDE HUNG
D8
DOOR DOUBLE FOLDING
48"
72"
45"
70.5"
00"
SIDE HUNG
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
SHEET TITLE:
D9
DOOR DOUBLE FOLDING
42"
72"
39"
70.5"
00"
SIDE HUNG
W1
WINDOW
48"
46"
45"
43"
32"
UPWARD SLIDE
W2
WINDOW
42"
46"
39"
43"
32"
UPWARD SLIDE
W3
WINDOW
39"
46"
36"
43"
32"
UPWARD SLIDE
W4
WINDOW
25"
46"
22"
43"
32"
UPWARD SLIDE
W5
WINDOW
25"
46"
22"
43"
34"
UPWARD SLIDE
PROPOSED
BASEMENT FLOOR
ARCHITECTURAL
PLAN
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
CHECKED:
SJ & AG
A-11
DWG. NO.
11 OF 13
REVISIONS
NO.
27'-10"
PARAPET TOP
DATE
DESCRIPTION
8"
3'-7"
PARAPET WALL
23'-7"
SECOND FLOOR
CEILING ON FRONT
4'-6"
2'-8"
ARCHITECT:
TRIM BOARD (OPTIONAL)
12'-2"
13'-2"
FIRST FLOOR CEILING
CORNER BOARD (OPTIONAL)
1'
14'-2"
SECOND FLOOR
27'-10"
9'-5"
HARDIE SMOOTH LAP SIDING
W/ 4" EXPOSURE
AUGUSTUS GEHRY
ARCHITECT
2'-10"
ARCHITECTURE
INTERIOR DESIGN
10"
1'-0"
FIRST FLOOR
0'-2"
BASEMENT CEILING
8'-1"
7'-11"
0'-0"
FINISHED ROAD
LEVEL
-(7'-11")
BASEMENT FLOOR
39'-97
8"
1'
FRONT ELEVATION
CONSULTANTS:
SCALE 1/4" = 1'
27'-10"
PARAPET TOP
3'-7"
27'-2"
SECOND FLOOR CEILING ON FRONT
8"
PLAN REVIEW INFO:
9'-5"
23'-7"
SECOND FLOOR
CEILING ON FRONT
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
22
1'
13'-2"
FIRST FLOOR CEILING
2'-8"
27'-10"
14'-2"
SECOND FLOOR
PROJECT:
-
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
14
13
12'-2"
12
11
10
2'-8"
-
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
10"
1'-0"
FIRST FLOOR
FOR
10"
0'-2"
BASEMENT CEILING
0'-0"
FINISHED ROAD
LEVEL
8'-1"
7'-11"
SHEET TITLE:
EXISTING
ELEVATIONS
WITH PROPOSED
DETAILS
-(7'-11")
BASEMENT FLOOR
100'-6"
RIGHT ELEVATION
SCALE 1/4" = 1'
6'-2"
11'-111
2"
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
CHECKED:
SJ & AG
A-12
DWG. NO.
12 OF 13
REVISIONS
27'-10"
SECOND FLOOR
CEILING ON BACK
NO.
PARAPET WALL
DATE
DESCRIPTION
TRIM BOARD (OPTIONAL)
13'-8"
HARDIE SMOOTH LAP SIDING
W/ 4" EXPOSURE
ARCHITECT:
1'
-
12'-2"
13'-2"
FIRST FLOOR CEILING
2'-10"
27'-10"
14'-2"
SECOND FLOOR
CORNER BOARD (OPTIONAL)
AUGUSTUS GEHRY
ARCHITECT
08
07
06
ARCHITECTURE
INTERIOR DESIGN
05
2'-8"
04
1'-0"
FIRST FLOOR
03
02
10"
01
0'-2"
BASEMENT CEILING
8'-1"
7'-11"
0'-0"
FINISHED ROAD
LEVEL
-(7'-4")
BASEMENT FLOOR
38'-85
8"
2'-11
4"
REAR ELEVATION
CONSULTANTS:
SCALE 1/4" = 1'
27'-10"
PARAPET TOP
3'-7"
27'-2"
SECOND FLOOR CEILING ON FRONT
8"
PLAN REVIEW INFO:
2'-8"
27'-10"
9'-5"
23'-7"
SECOND FLOOR
CEILING ON FRONT
1'
22
21
PROJECT:
14'-2"
SECOND FLOOR
13'-2"
FIRST FLOOR CEILING
20
19
18
MULTIFAMILY
DEVELOPMENT IN
EXISTING BUILDING
BLOCK 10304, LOT 3
-
346 CENTRE ST,
TRENTON, MERCER
COUNTY N.J 08611
13
12'-2"
-
10"
2'-8"
FOR
1'-0"
FIRST FLOOR
MR. SHMIEL JACOBOWITZ
&
MR. AZREIL GROSSMAN
0'-2"
BASEMENT CEILING
7'-11"
8'-1"
0'-0"
FINISHED ROAD
LEVEL
-(7'-11")
BASEMENT FLOOR
11'-111
2"
6'-2"
100'-6"
LEFT ELEVATION
SCALE 1/4" = 1'
SHEET TITLE:
EXISTING
ELEVATIONS
WITH PROPOSED
DETAILS
DATE:-
PROJECT NO.
01
SCALE:
AS NOTED
SHEET NO.
DRAWN:
MI
CHECKED:
SJ & AG
A-13
DWG. NO.
13 OF 13