NextDC - Stage 2 Building Awning
BOX GUTTER 300X150mm WITH 300X100mm
SUMP AT THE END.
35X50X35-1.15 TOPHAT FIXED TO THE ZINCALUM
ANGLE AND PURLIN WITH 4NOs OF SS304
#12-16X21 HEX TEK SCREWS TO SUPPORT THE
FC SHEET.
9mm FC SHEET TO SUPPORT THE
MAINTENANCE LOAD.
15X50X15-1.15THK TOPHAT @JOINTS
FIXED TO THE PURLIN WITH 4NOs OF THE
SS304 #12-16X21 HEX TEK SCREWS
802
50mm THICK NON-COMBUSTIBLE
INSULATION.
PRESSURE SEALED APRON
FLASHING TO THE CONCRETE
02
RL TOP 87100
WATERPROOFING MEMBRANE BY
OTHERS
801
470
SS304 #12-16X21 HEX TEK SCREWS TO THE
STEEL PURLIN SPACING TBC
35X50X35-1.15 TOPHAT BRACING EVERY
4th JOINT.
1162
100
150
SUMP GUTTER
FFL LEVEL 2A
87000
35X50X35-1.15 TOPHAT AT JOINTS
FIXED TO THE STEEL PURLINs BY
SS304 #12-16X21 HEX TEK
SCREWS.
-
767
NON COMBUSTIBLE FIREFLY
SARKING OVER THE WIRE
MESH
PRESSURE SEALED FLASHING TO
THE CONCRETE
KLIP-LOK 700 Hi STRENGTH
ROOFING SHEET IN BASALT FIXED
TO THE TOPHAT
2
MC-02 SMOKE SILVER
METALLIC
VITRADUAL 3mm
KLIP-LOK 700 Hi STRENGTH
ROOFING SHEET IN BASALT FIXED
TO THE TOPHAT
NON COMBUSTIBLE FIREFLY SARKING OVER
THE WIRE MESH
50X70X1.2 ZINCALUM
CONTINUOUS ANGLE
CONNECTING THE
TOPHAT BY 4NOs SS304
OF #12-16X21 HEX TEK
SCREWS.
MC-01 POPPY RED
VITRADUAL 3mm
66°
850
3
VARIES.
20
313
2401
45X20X1.6 ALUMINIUM STIFFENER @500mm C/C
ADHERED TO BACK OF PANEL USING SIKA 11-FC.
SCALE: 1:8
802
45X20X1.6 ALUMINIUM
STIFFENER @500mm C/C
MECHANICALLY FIXED TO THE
SIDES RETURNS.
35X50X35-1.15 TOPHAT @ JOINTS FIXED
TO THE PURLIN OR TOPHAT WITH 2NO's
OF SS304 #12-16X21 HEX TEK SCREWS.
15X50X15-1.15THK TOPHAT @JOINTS
FIXED TO THE PURLIN WITH 4NOs OF THE
SS304 #12-16X21 HEX TEK SCREWS
2
DETAIL
801
SCALE: 1:1
1951
29
QUAD FOLDING CHANNEL BY OTHERS
35X50X35-1.15 TOPHAT FIXED TO THE ZINCALUM
ANGLE AND PURLIN @ JOINTS WITH 4NOs OF
SS304 #12-16X21 HEX TEK SCREWS TO
SUPPORT THE FC SHEET.
MC-01 VITRADUAL IN POPPY RED
FIXED TO THE TOPHAT BY SS304
#12-16X24 @300mm C/C.
465
20
MC-01 VITRADUAL IN POPPY RED
FIXED TO THE TOPHAT BY SS304
#12-16X24 @300mm C/C.
1
RL SOFFIT
86000
15
1407
STAGE 01 LEVEL 2 AWNING DETAIL
680
15
1984
MC-01 VITRADUAL IN POPPY RED
FIXED TO THE TOPHAT BY SS304
#12-16X24 @300mm C/C.
66
APRON FLASHING FIXED TO THE
PURLIN
35X50X35-1.15 TOPHAT @ MAX 850mm
C/C FIXED TO THE U/S OF SLAB BY M10
BOOKER ROD MIN 70mm EMBEDMENT.
4NOs OF SS304 #14-16X21 HEX
TEK SCREWS.
35X50X35-1.15 TOPHAT @ MAX 850mm
C/C FIXED TO THE U/S OF SLAB BY M10
BOOKER ROD MIN 70mm EMBEDMENT.
4NOs OF SS304 #14-16X21 HEX
TEK SCREWS.
35X50X35-1.15 TOPHAT @ JOINTS FIXED
TO THE TOPHAT WITH 4NO's OF SS304
#14-16X21 HEX TEK SCREWS.
3
DETAIL
801
SCALE: 1:1
..\..\..\..\3_ADMINISTRATION\Client Logos\ACS LOGO-small.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\Multiplex Narrow.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\greenbox-logo.png
GLAZING SYSTEM BY OTHERS
..\..\..\..\3_administration\client logos\nextdc.png
AUSTRALIAN CLADDING SPECIALISTS Pty. Ltd
Address:
207- 122 LANG Rd. MOORE PARK, NSW, 2021
Phone: -
21X
20
861
X12
168
21X
CONTINUOUS C200X12
STEEL BY OTHERS
RL SOFFIT
86300
X12
Ø10 mm WEEP HOLE
1
801
25X50X25-1.15 TOPHAT AT JOINTS FIXED TO
THE STEEL PURLINs BY SS304 #12-16X21 HEX
TEK SCREWS.
FOR CONSTRUCTION
MC-01 POPPY RED
VITRADUAL 3mm
9mm FC SHEET TO SUPPORT THE
MAINTENANCE LOAD.
600X470mm SUMP AT THE END OF OF
THE BOX GUTTER.
35X50X35-1.15 TOPHAT FIXED TO THE ZINCALUM
ANGLE AND PURLIN 3 PER PANEL WIDTH (MAX
300mm C/C) BY 4NOs OF SS304 HEX TEK
SCREWS TO SUPPORT THE FC SHEET.
15X50X15-1.15 TOPHAT FIXED TO THE ZINCALUM
ANGLE AND PURLIN @ JOINTS WITH 4NOs OF
SS304 #12-16X21 HEX TEK SCREWS.
2
802
70X70X1.2 ZINCALUM CONTINUOUS
ANGLE FIXING VERTICAL TO THE
HORIZONTAL TOPHAT BY 4 NOs OF
SS304 OF #12-16X21 HEX TEK SCREWS
@600mm.
801
FFL LEVEL 3
91000
470X150mm BOX GUTTER.
MC-01 VITRADUAL IN POPPY RED
FIXED TO THE TOPHAT BY SS304
#12-16X24 @300mm C/C.
03
KLIP-LOK 700 Hi STRENGTH
ROOFING SHEET IN BASALT FIXED
TO THE TOPHAT
PRESSURE SEALED APRON
FLASHING TO THE CONCRETE
KLIP-LOK 700 Hi STRENGTH ROOFING
SHEET IN BASALT FIXED TO PURLIN.
MC-02 SMOKE SILVER
METALLIC
VITRADUAL 3mm
WATERPROOFING MEMBRANE BY OTHERES
PRESSURE SEALED APRON
FLASHING TO THE CONCRETE
NON COMBUSTIBLE FIREFLY
SARKING OVER THE WIRE
MESH
470
1095
640
100
150
SUMPS GUTTER
100
SS304 #10-16X20mm FLAT
HEAD TEK SCREW
@300mm C/C.
675
1095
1000
NON COMBUSTIBLE FIREFLY
SARKING OVER THE WIRE
MESH
C05
545
35X50X35-1.15 TOPHAT AT JOINTS FIXED TO
THE STEEL PURLIN BY SS304 #12-16X21 HEX
TEK SCREWS.
GLAZING SYSTEM BY OTHERS.
50X50X1.2 ZINCALUM CONTINUOUS
ANGLE FIXED TO THE PURLIN BY
SS304 #12-16X21 HEX TEK SCREWS
@600mm C/C.
63
98
128
SS304 #12-16X20mm HEX TEK
SCREW @600mm C/C
RL SOFFIT
90000
Ø10 mm WEEP HOLE
445
170
3080
20
20
3257
35X50X35-1.15 TOPHAT AT JOINTS FIXED TO
THE STEEL PURLIN BY SS304 #12-16X21 HEX
TEK SCREWS.
1
681
OVERFLOW
MC-01 VITRADUAL IN POPPY RED
FIXED TO THE TOPHAT BY SS304
#12-16X24 @300mm C/C.
STAGE 01 LEVEL 3 AWNING DETAIL
15X50X15-1.15 TOPHAT FIXED TO THE ZINCALUM
ANGLE AND PURLIN @ JOINTS WITH 2NOs OF
SS304 HEX TEK SCREWS.
SCALE: 1:8
Ø10 mm WEEP HOLE
45X20X1.6 ALUMINIUM STIFFENER @500mm C/C
ADHERED TO BACK OF PANEL USING SIKA 11-FC
45mm BITE.
9mm FC SHEET TO SUPPORT THE
MAINTENANCE LOAD.
35X50X35-1.15 TOPHAT FIXED TO THE ZINCALUM
ANGLE AND PURLIN 3 (MAX 300mm C/C) PER
PANEL WIDTH BY 4NOs OF SS304 HEX TEK
SCREWS TO SUPPORT THE FC SHEET.
20
9mm FC SHEET TO SUPPORT THE
MAINTENANCE LOAD.
APRON FLASHING FIXED TO THE PURLUN.
70X70X1.2 ZINCALUM CONTINUOUS
ANGLE FIXING VERTICAL TO THE
HORIZONTAL TOPHAT BY 2 NOs OF
SS304 OF #12-16X21 HEX TEK
SCREWS.
NON COMBUSTIBLE FIREFLY
SARKING OVER THE WIRE
MESH
2
802
FC SUPPORT DETAIL
SCALE: 1:2
KLIP-LOK 700 Hi STRENGTH
ROOFING SHEET FIXED TO THE
TOPHAT
3
DETAIL
802
SCALE: 1:2
..\..\..\..\3_ADMINISTRATION\Client Logos\ACS LOGO-small.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\Multiplex Narrow.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\greenbox-logo.png
..\..\..\..\3_administration\client logos\nextdc.png
AUSTRALIAN CLADDING SPECIALISTS Pty. Ltd
Address:
207- 122 LANG Rd. MOORE PARK, NSW, 2021
Phone: -
FOR CONSTRUCTION
MC-01 POPPY RED
VITRADUAL 3mm
MC-02 SMOKE SILVER
METALLIC
VITRADUAL 3mm
A
15X50X15-1.15 TOPHAT FIXED TO THE ZINCALUM
ANGLE AND PURLIN @ JOINTS WITH 4NOs OF
SS304 #12-16X21 HEX TEK SCREWS.
#10-16X20mm SS A4-70 FLAT HEAD
TEK SCREW FIXED THE PANEL TO
THE HEAD TRACK AT 300mm C/C.
Tek Screw
35X50X35-1.15 TOPHAT FIXED TO THE ZINCALUM
ANGLE AND PURLIN 3 PER PANEL WIDTH(MAX
300mm C/C) BY 4NOs OF SS304 HEX TEK
SCREWS TO SUPPORT THE FC SHEET.
92mm STUD AND TRACK SYSTEM
FIXED TO THE CONCRETE SLAB BY
M10-70 CONCRETE SCREW
ANCHOR AT 1000mm C/C. STUDS
@600mm C/C.
ANGLE TO THE BOTTOM OF THE
LOUVRE SYSTEM BY OTHERS.
PRESSURE SEALED APRON
FLASHING FIXED TO THE
CONCRETE WITH 6.5 SS
MUSHROOM PIN @ 1000mm C/C
AND SEALED AGAINST THE BOX
GUTTER WALL.
760
FFL LEVEL 4
96000
2107
400X100 BOX GUTTER
WITH 90MM SUMP AT THE
END.
300
2
802
Tek Screw
865
100
RL : 95700
100
60
90
100
GUTTER SUMP
9mm FC SHEET TO SUPPORT THE
MAINTENANCE LOAD.
TK-14x32
400
680
STEEL STRUCTURE BY OTHERS
66°
151
25X50X25-1.15 TOPHAT AT JOINTS FIXED TO
THE STEEL PURLIN BY 4NOs OF SS304
#12-16X21 HEX TEK SCREWS.
70X70X1.2 ZINCALUM L=100mm ANGLE
FIXED THE TOPHAT T TNE 1.2 ZINALUM
ANGLE BY 4NOs OF SS304 #12-16X21
HEX TEK SCREW
Ø10 mm WEEP HOLE
1
682
STAGE 01 LEVEL 4 AWNING DETAIL
SCALE: 1:8
235
180
746
#10-16X20mm SS A4-70 FLAT HEAD
TEK SCREW @300mm C/C.
1710
FACE OF CONCRETE SLAB
1559
20
306
1801
RL SOFFIT
95020
MC-02 VITRADUAL IN SMOKE SILVER
METALLIC
FIXED TO THE TOPHAT BY SS304
#12-16X24 @300mm C/C.
100X50X1.2 ZINCALUM ANGLE FIXED
TO THE UNDERSIDE OF THE
CONCRETE WITH M10X70 CONCRETE
SCREW ANCHOR AT MAX 1000mm C/C
20
13
45X20X1.6 ALUMINIUM STIFFENER @500mm C/C
ADHERED TO BACK OF PANEL USING SIKA 11-FC
45mm BITE.
100X50X1.2 ZINCALUM ANGLE FIXED
TO THE 1.2 ANGLE WITH SS304
#12-16X21 HEX TEK SCREW AT MAX
450mm C/C.
Ø10 mm WEEP HOLE
GLAZING SYSTEM BY OTHERS.
OVER FLOW PIPE.
..\..\..\..\3_ADMINISTRATION\Client Logos\ACS LOGO-small.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\Multiplex Narrow.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\greenbox-logo.png
..\..\..\..\3_administration\client logos\nextdc.png
AUSTRALIAN CLADDING SPECIALISTS Pty. Ltd
Address:
207- 122 LANG Rd. MOORE PARK, NSW, 2021
Phone: -
FOR CONSTRUCTION
MC-01 POPPY RED
VITRADUAL 3mm
A
MC-03 SATIN BLACK
METALLIC
VITRADUAL 3mm
4058
18
20
900
180
20
2582
RL TOP
91100
766
700
L2A+87000
1100
20
SB14
4A
A
2939
FSL
91000
L3+91000
SB
14
22
L2+86000
SB17
1960
SC10
20
20
SB17
1093
600
1325
1210
SC10
1000
SC10
RL SOFFIT
90720
22
1066
994
600
600
600
1066
20
22
974
600
66°
1066
600
20
20
668
66°
766
22
20
300
170
700
30
30
610
22
1354
2217
650
805
L2A+87000
136
1
1
600
1325
1210
22
600
974
600
20
22
600
0
1325
1210
22
5020
RL SOFFIT
90000
RL SOFFIT
89957
20
L2+86000
2
LEVEL 2 VERTICAL WALL WESRTERN SIDE
SCALE: 1:20
RL SOFFIT
86300
680
LEVEL 3 VERTICAL WALL EASTERN SIDE
SCALE: 1:20
..\..\..\..\3_ADMINISTRATION\Client Logos\ACS LOGO-small.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\Multiplex Narrow.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\greenbox-logo.png
..\..\..\..\3_administration\client logos\nextdc.png
AUSTRALIAN CLADDING SPECIALISTS Pty. Ltd
Address:
207- 122 LANG Rd. MOORE PARK, NSW, 2021
Phone: -
FOR CONSTRUCTION
MC-01 POPPY RED
VITRADUAL 3mm
1A
300
20X20X1.6 THK CONTINUES ALUMINUM
ANGLE FIXED TO THE BACK OF
ALUMINUM PANEL BY SIKA-11FC
MC-02 SMOKE SILVER
METALLIC
VITRADUAL 3mm
416
20
170
170
716
20
02
3mm VITRADUAL SOLID ALUMINUM IN
POPPY RED
805
SS304 #12-16X21 HEX TEK SCREWS @
600mm.
SS304 #12-16X21 HEX TEK SCREWS @
600mm TO THE STEEL PURLINS
50X50X1.2 ZINCALUM REVERSE
ANGLES AT 450mm C/C FIXED TO THE
HORIZONTAL PURLINS BY SS304
#12-16X21 HEX TEK SCREWS.
SS304 #12-16X21 FLAT HEAD SCREW
@300mm C/C
202
202
214
98
VARIS.
SS304 #12-16X21 HEX TEK SCREWS AT
450mm C/C
450
20
2
150 C PURLINS AT 600mm C/C BY
ELMASRY STEEL SUB-CONTRACTOR
804
404
STRUCTURE DEPTH
450
50X50X50-1.15THK TOPHAT FIXED TO THE
BRACKET BY 2NOs OF SS 304 #12-16X21
HEX TEK SCREWS.
VARIS.
3030
50X50X1.2 ZINCALUM REVERSE
CONTINUOUS ANGLES AT 600mm C/C
FIXED TO THE HORIZONTAL PURLINS
BY SS304 304 #12-16X21 HEX TEK
SCREWS.
3mm VITRADUAL SOLID ALUMINUM IN
SMOKE SILVER METALLIC
STEEL PURLINS AT 600mm C/C BY
ELMASRY STEEL SUB-CONTRACTOR
0.75 ZINCALUM BACKPAN
NON-COMBUSTIBLE INSULATION
3mm VITRADUAL SOLID ALUMINUM IN
POPPY RED
STUD AND TRACK SYSTEM IN
BETWEEN STEEL MEMBERS TO THE
ENGINEERING SPEC.
2
805
0.75 ZINCALUM BACKPAN FLASHING
FULLY SEALED AGAINST CONCRETE
WALL
1
651
20X23X10 - 1.6 THK CONTINUES
ALUMINIUM Z PROFILE TO BE POWDER
COATED IN PUPPY RED FULLY BEDDED
IN SIKA 11-FC.
185
PLAN DETAIL
SCALE: 1:1
45X20X1.6 RHS ALUMINUM STIFFENER @
450mm C/C FIXED TO THE BACK OF
SOLID ALUMINUM PANEL.
CONTINUOUS SEALANT AGAINST
CONCRETE COLUMN.
WINDOW BY OTHERS
30
STEEL 6.5X50 HAMMER DRIVE PIN
@600mmC/C TO BE FULLY SEALED.
SS304 #12-16X21 FLAT HEAD SCREW
@300mm C/C.
3mm VITRADUAL SOLID ALUMINUM IN
POPPY RED
1157
55X48X55-1.9 THK BRACKET FIXED TO
THE STUDS BY 2 NOs OF SS 304
#12-16X21 HEX TEK SCREWS FULLY
SEALED TO THE BACKPAN.
50X50X1.2 ZINCALUM REVERSE
CONTINUOUS ANGLES.
40X25X10 - 1.6 THK CONTINUES
ALUMINIUM Z PROFILE TO BE POWDER
COATED IN PUPPY RED AND FULLY
BEDDED IN SIKA 11-FC.
A
LEVEL 02 DETAIL
SCALE: 1:8
..\..\..\..\3_ADMINISTRATION\Client Logos\ACS LOGO-small.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\Multiplex Narrow.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\greenbox-logo.png
..\..\..\..\3_administration\client logos\nextdc.png
AUSTRALIAN CLADDING SPECIALISTS Pty. Ltd
Address:
207- 122 LANG Rd. MOORE PARK, NSW, 2021
Phone: -
FOR CONSTRUCTION
NOTE: PANELS WIDER THAN 450mm WIDTH ON THE BLADES SHOULD HAVE
45X20X1.6 STIFFENERS AT 600mm C/C UNLESS NOTED OTHERWISE.
716
MC-01 POPPY RED
VITRADUAL 3mm
1A
MC-02 SMOKE SILVER
METALLIC
VITRADUAL 3mm
1A
300
20
416
400
200
35X50X35-1.15THK TOPHAT FIXED TO THE
BRACKET BY 2NOs OF SS 304 #12-16X21
HEX TEK SCREWS.
VERTICAL SPACING 450mm C/C.
450
930
20
220
450
MC-03 SATIN BLACK
METALLIC
VITRADUAL 3mm
930
3mm VITRADUAL SOLID ALUMINUM IN
POPPY RED
200
2533
45X20X1.6 RHS ALUMINUM STIFFENER @
600mm C/C FIXED TO THE BACK OF
SOLID ALUMINUM PANEL.
200
20
490
20
140
245
20
3mm VITRADUAL SOLID ALUMINUM IN
SMOKE SILVER METALLIC
300
3mm VITRADUAL SOLID ALUMINUM IN
SATIN BLACK.
20
200
433
100X100X1.2 THK CONTINUES
ZINCALUM ANGLE FIXED TO THE
STEEL STRUCTURE BY SS304
#12X16-40 @1000mm C/C
400
50X50X50-1.15THK TOPHAT FIXED TO THE
BRACKET BY 2NOs OF SS 304 #12-16X21
HEX TEK SCREWS.
3030
20
20X20X1.6 THK CONTINUES ALUMINUM
ANGLE FIXED TO THE BACK OF
ALUMINUM PANEL BY SIKA-11FC
180
330
0.75 ZINCALUM BACKPAN
20
0.75 ZINCALUM BACKPAN FLASHING
FULLY SEALED AGAINST CONCRETE
WALL
1100
1157
STEEL 6.5X50 HAMMER DRIVE PIN
@600mmC/C TO BE FULLY SEALED.
900
715
55X48X55-1.9 THK BRACKET FIXED TO THE STUDS BY 2
NOs OF SS 304 #12-16X21 HEX TEK SCREWS FULLY
SEALED TO THE BACKPAN.
40X40X1.2 ZINCALUM CONTINUOUS
ANGLE FIXED TO THE CONCRETE
COLUMN BY M8-50 CONCRETE SCREW
ANCHOR AT 1000mm C/C.
0.75 ZINCALUM BACKPAN FLASHING
FULLY SEALED AGAINST CONCRETE
WALL
1
654
120X50X1.2 THK CONTINUES
ZINCALUM ANGLE FIXED TO THE
STEEL STRUCTURE BY SS304
#12X16-40 @600mm C/C
1100
1157
STUD AND TRACK SYSTEM IN
BETWEEN STEEL MEMBERS TO THE
ENGINEERING SPEC.
55
NON-COMBUSTIBLE INSULATION
M8 CONCRETE BOLT @1000mm C/CFIX
CONTINUOUS VERTICAL 1.2 ZINCALUM
ANGLE TO THE CONCRETE
20X20X1.6 THK CONTINUES ALUMINUM
ANGLE FIXED TO THE BACK OF
ALUMINUM PANEL BY SIKA-11FC
20
3710
35X48X35-1.9 THK BRACKET @600mm
HORIZONTAL MAX FIXED TO THE
STEEL STRUCTURE BY 2 NOs OF SS
304 #12-16X21 HEX TEK SCREWS.
45X20X1.6 RHS ALUMINUM STIFFENER @
600mm C/C FIXED TO THE BACK OF
SOLID ALUMINUM PANEL.
LOUVRE SYSTEM BY OTHERS
A
WATERPROOFING BY OTHERS
A
2
LEVEL 03 DETAIL GRID 1A
SCALE: 1:8
LEVEL 04 DETAIL GRID 1A
658
SCALE: 1:8
..\..\..\..\3_ADMINISTRATION\Client Logos\ACS LOGO-small.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\Multiplex Narrow.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\greenbox-logo.png
..\..\..\..\3_administration\client logos\nextdc.png
AUSTRALIAN CLADDING SPECIALISTS Pty. Ltd
Address:
207- 122 LANG Rd. MOORE PARK, NSW, 2021
Phone: -
FOR CONSTRUCTION
NOTE: PANELS WIDER THAN 450mm WIDTH ON THE BLADES SHOULD HAVE
45X20X1.6 STIFFENERS AT 600mm C/C UNLESS NOTED OTHERWISE.
5A
MC-01 POPPY RED
VITRADUAL 3mm
400
1A
200
200
MC-03 SATIN BLACK
METALLIC
VITRADUAL 3mm
400
200
450
313
200
20
180
900
1100
665
HEAVY DUTY 150mm STUD 1.15THK @1000mm
C/C FIXED TO THE TRACK BY 2NOs OF SS304
#12-16X21
45X20X1.6 RHS ALUMINUM STIFFENER
@600mm C/C FIXED TO THE BACK OF SOLID
ALUMINUM PANEL.
477
20
20
1100
HEAVY DUTY 150mm TRACK 1.15THK FIXED TO
THE CONCRETE WITH M10-70 SCREW ANCHOR
BOLT @1000mm C/C
930
480
55X48X55-1.9 THK BRACKET @MAX 1000mm
FIXED TO THE STEEL MEMBER BY SS304
#12-16X24 HEX TEK SCREWS.
259
45X20X1.6 RHS ALUMINUM STIFFENER
@600mm C/C FIXED TO THE BACK OF SOLID
ALUMINUM PANEL.
656
20
20
35X50X35-1.15THK TOPHAT FIXED TO THE
STUD BY 2NOs OF SS 304 #12-16X21 HEX
TEK SCREWS.
VERTICAL SPACING @1000mm C/C.
20
180
20
135
20
135
35X50X35-1.15THK TOPHAT FIXED TO THE
BRACKET BY 2NOs OF SS 304 #12-16X21
HEX TEK SCREWS.
254
289
20
289 480
100X50X1.2 CONTINUOUS ZINCALUM ANGLE
FIXED TO THE STEEL STRUCTURE WITH SS304
#12-16X21 HEX TEK SCREWS AT 1000mm C/C
Tek Screw
#12 x 20
#12 x 20
40X40X1.2 ZINCALUM STRUCTURAL ANGLE FIXED
TO THE CONCRETE BY M8-50 CONCRETE SCREW
@1000mm C/C.
HEAVY DUTY 150mm STUD 1.15THK @1000mm
C/C FIXED TO THE TRACK BY 2NOs OF SS304
#12-16X21
64
SCALE: 1:8
0.75 ZINCALUM BACKPAN FLASHING
FULLY SEALED AGAINST CONCRETE
WALL AND MULLION AND OVERLAPPED
OVER THE BRACKET
STEEL 6.5X50 HAMMER DRIVE PIN
@600mmC/C TO BE FULLY SEALED.
1100
900
50X50X1.2 CONTINUOUS ZINCALUM ANGLE FIXED
TO THE CONCRETE COLUMN BY M8-50 CONCRETE
SCREW @1000mm C/C.
HEAVY DUTY 150mm TRACK 1.15THK FIXED TO
THE CONCRETE WITH M8-50 CONCRETE SCREW
@1000mm C/C
35X50X35-1.15THK TOPHAT FIXED TO THE
BRACKET BY 2NOs OF SS 304 #12-16X21
HEX TEK SCREWS.
650
SIM.
GRID 5A LEVEL 3
Tek Screw
85
1
100X50X1.2 CONTINUOUS ZINCALUM ANGLE
FIXED TO THE 1.15mm TRACK WITH SS304
#12-16X21 HEX TEK SCREWS AT 1000mm C/C
20
45X20X1.6 RHS ALUMINUM STIFFENER
@600mm C/C FIXED TO THE BACK OF SOLID
ALUMINUM PANEL.
20
135
20
135
20
490
55X48X55-1.9 THK BRACKET @1000mm VERTICAL
FIXED TO THE CONCRETE BY M8-50 CONCRETE
SCREW ANCHOR.
553
665
30
15
35X50X35-1.15THK TOPHAT FIXED TO THE
BRACKET BY 2NOs OF SS 304 #12-16X21
HEX TEK SCREWS.
A
55X48X55-1.9 THK BRACKET @1000mm VERTICAL
FIXED TO THE CONCRETE BY M8-50 CONCRETE
SCREW ANCHOR.
45X20X1.6 RHS ALUMINUM STIFFENER
@600mm C/C FIXED TO THE BACK OF SOLID
ALUMINUM PANEL.
2
SIM.
85
GRID 5A LEVEL 4 TO ROOF DETAIL
20
SCALE: 1:8
..\..\..\..\3_ADMINISTRATION\Client Logos\ACS LOGO-small.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\Multiplex Narrow.jpg
..\..\..\..\3_ADMINISTRATION\Client Logos\greenbox-logo.png
..\..\..\..\3_administration\client logos\nextdc.png
AUSTRALIAN CLADDING SPECIALISTS Pty. Ltd
Address:
207- 122 LANG Rd. MOORE PARK, NSW, 2021
Phone: -
40X40X1.2 ZINCALUM STRUCTURAL ANGLE FIXED
TO THE CONCRETE BY M8-50 CONCRETE SCREW
@1000mm C/C.
FOR CONSTRUCTION